beautypg.com

Appending data, Details of appended data, Read data format – KEYENCE SR-750 Series User Manual

Page 64: Data size, Time, Read detailed error code, Code type, Symbol id, Parameter bank number, Burst number

background image

64

E SR-750 UM

Appending Data

Various types of data can be appended to read data.

„

Read data format

The data format for appending various types of data to read data is shown below:

Delimiter characters
• The colon (:) as a delimiting character can be changed via AutoID Network

Navigator (one character).

• No delimiter character is inserted after "Data size" and "Symbol ID", and before

"Checksum".

Precautions when appending data
• Appended data can be set via a command or from AutoID Network Navigator.
• Only the selected data will be appended to the read data. The data size changes

because of this.

• Checksum defers by the contents of the appended data.

Details of Appended Data

„

Data size

The data size is the total size of parts (1), (2), and (3), plus 4 bytes.

„

Time

Appends the time the data was output.
Appended data range: YYYYMMDDhhmmss
• Data format

„

Read detailed error code

Factors that caused read errors are judged for each burst number.
The Read detailed error code is appended before the Read data.

n: Maximum value of the burst No.

• The detailed error code is appended starting with burst No. 1.
• The detailed error code is appended with the following contents.

„

Code type

The type of read code can be appended before the read data.

Data

size

Time :

Detail error

code

:

Code

type

:

Symbol

ID

Read

data

:

Parameter

bank

numbers

:

Burst

number

:

Scan

count

:

Positioning

level

:

Code vertex
coordinates

:

Code center
coordinates

:

Unused

ECC
ratio

:

Matching

level

:

ISO/IEC15415

verification

result

:

ISO/IEC TR 29158
(AIM DPM-1-2006)
verification result

:

SAE AS9132

verification

result

:

SEMI T10-0701

verification

result

:

Image

file name

:

Group

name

:

Master/

Slave ID

:

Read

time

Check-

sum

YYYYMMDDhhmms :

Read data

Burst number 1

detailed error code

:

Burst number 2

detailed error code

:

:

Burst number n

detailed error code

:

Read data

Detailed error code

Description

0

Reading success

1

No code

2

The set decode timeout period elapsed.

3

Scanning aborted.

9

Reading images failed.

Code type ID

Read data

0

Reading error

1

QR

2

DataMatrix

5

GS1 DataBar

6

CODE39

7

ITF

9

NW-7(Codabar)

10

JAN/EAN/UPC

11

CODE128

(3)

(2)

(1)

Header

Data size

Read data + appended data

Termi-

nator

Checksum

„

Symbol ID

Appends the symbology identifier, specified by AIM, before the read data.
It is not appended when a reading has failed.
• Data format

„

Parameter bank number

Appends the parameter bank number that was read.
It is not appended when a reading fails.
• Data format

nn = parameter bank number (01 - 10)

„

Burst number

Outputs the burst number of the successfully read image in the burst read mode.
No data is appended for a failed reading.
This data is not appended in any mode other than the burst read mode.
• Data format

n = burst number (1 - 8)

„

Scan count

Appends the number of reading attempts of the SR-750 Series while the timing
input is turned ON.
Failed reading operations are also counted.
• Data format

nnnnn = scan count (1 - 65535)

„

Position level

Appends the position level of the read code.
When several codes are read for one scan (multi read), the average of all code
position levels is output.
0 is appended when a reading fails.
• Data format

n = position level value (0 - 5)

Symbol ID

Read data

Code type

Detail

Symbol ID

QR

: Model 1

]Q0

: Model 2, ECI not applied

]Q1

: Model 2, ECI applied

]Q2

: Model 2, ECI not applied, FNC1 (1st)

]Q3

: Model 2, ECI applied, FNC1 (1st)

]Q4

: Model 2, ECI not applied, FNC1 (2nd)

]Q5

: Model 2, ECI applied, FNC1 (2nd)

]Q6

DataMatrix

: ECC 200

]d1

: ECC 200, FNC1 (1st)

]d2

: ECC 200, FNC1 (2nd)

]d3

: ECC 200, ECI applied

]d4

: ECC 200, ECI applied, FNC1 (1st)

]d5

: ECC 200, ECI applied, FNC1 (2nd)

]d6

CODE39

No check digit validation

]A0

Check digit is validated and transmitted.

]A1

Check digit is validated but not transmitted.

]A3

ITF

No check digit validation

]I0

Check digit is validated and transmitted.

]I1

Check digit is validated but not transmitted.

]I3

NW-7(Codabar)

]F0

JAN/EAN/UPC

UPC-A, UPC-E, JAN/EAN13

]E0

JAN/EAN8

]E4

UPC-A, UPC-E, JAN/EAN13
Addon 2, addon 5

]E3

CODE128

FNC1 not included.

]C0

FNC1 on the first digit (GS1-128).

]C1

FNC1 on the second digit.

]C2

GS1 Databar

]e0

Read data

:

nn

Read data

:

n

Read data

:

nnnnn

Read data

:

level = n