Misc – KEYENCE SR-750 Series User Manual
Page 48
48
E SR-750 UM
• Keep connected
Check this option to let reader send connection requests whenever the
connection is closed.
Default
: Disabled
Setting range : Disable or Enable
• Send NOOP command
Sets whether to send NOOP commands periodically.
Default
: Enable
Setting range : Disable or Enable
• NOOP command interval (minutes)
Sets the sending interval for NOOP commands.
Default
: 1 minute
Setting range : 1 to 10 (minutes)
Misc
• Output data on TEST button
Sets the data output when the TEST button is pressed.
Default
: Enable
Setting range : Disable or Enable
• Filling size
Sets the data filling size. This fills the missing digits with the specified data filling
characters when the read data is less than the set size.
Default
: 0
Setting range : 0 to 999
• Filling character
Sets the data filling characters.
Default
: 20 (hexadecimal display, ASCII characters "(SP)")
Setting range : Enter any single ASCII or hexadecimal characters.
• Silent Mode
Set this option to enable silent mode.
Default
: Not selected
Setting range : Comparison OK and Read OK, Comparison NG, Read ERROR,
Stable Reading (OK/Comparison NG), Unstable Reading (OK/
Comparison NG), Preset Result, or Test mode
• Reader
Sets the reader name.
Default
: READER
Setting range : Up to 8 characters
• Monitor output data priority display position
Sets the monitor output data priority display position.
Default
: Forward
Setting range : Forward or Backward
• TUNE button
Sets Enable/Disable of the TUNE button.
Default
: Unlock
Setting range : Unlock or Lock
• Laser-aim option with TUNE button
Sets the pointer lighting condition by TUNE button operation.
Default
: By operation
Setting range : Lock .............................The laser pointer does not light up by
TUNE button operation or each operation
mode.
Test mode only ............Only in the test mode, the pointer lights
up by the TUNE button.
Run mode only ............Only in the run mode, the pointer lights
up by the TUNE button.
By operation ................Regardless of the test mode or the run
mode, the pointer lights up by the TUNE
button.
• Display bank number
Sets the parameter bank number display of reading success for the multiple LED
indicator.
Default
: Enable
Setting range : Enable or Disable
Trigger command response
• Specify response character
Sets the LON and LOFF trigger command response.
Default
: Disable
Setting range : Disable, SR-600 compatible and User setting
• SR-600 compatible
Set this option to enable the SR-600 compatible mode. For details, refer to
"3-9 SR-600 Compatible Output Mode (Page 19)".
• User setting
Sets the response for the following commands to Success response character
or Failure response character.
• LON
• LONmm
• LOFF
• PRON
• PROFF
• RESET
• BCLR
• Success response character
Sets the response character string when LON and LOFF is normally processed.
Default
: OK (0x4F4B)
Setting range : Up to 8 characters
Set with ASCII or HEX.
• Failure response character
Sets the response character string when the process (e.g. LON is sent during
LON. LOFF is sent during reading standby.) fails.
Default
: ER (0x4552)
Setting range : Up to 8 characters
Set with ASCII or HEX.
SNTP
• SNTP server address
Sets the SNTP server address.
• Time zone
Sets the time zone of the country where SR-750 is used.
Default
: +9:00 Japan, Seoul
• Update cycle (min)
Sets the time update cycle.
Default
: 1
Setting range : 1 to 99