TIMING
• Timing Mode
Sets the method of measuring timing.
Default
: Level trigger
Setting range : Level trigger or One-shot trigger
• One-shot trigger duration
Sets the measuring duration of one-shot trigger.
Default
: 1000 ms
Setting range : 30 to 25500 ms (in units of 10 ms)
• Timing ON command
Sets the timing ON command characters.
Default
: 4C4F4E (hexadecimal display, ASCII characters "LON")
Setting range : Enter a string using 8 or less ASCII or hexadecimal characters as
desired.
• Timing OFF command
Sets the timing OFF command characters.
Default
: 4C4F4646 (hexadecimal display, ASCII characters "LOFF")
Setting range : Enter a string using 8 or less ASCII or hexadecimal characters as
desired.
• One-character timing recognition
Set to enable one-character timing recognition.
Default
: Disable
Setting range : Disable or Enable
Important
The following strings can recognize a timing ON/OFF command as
one-character:
Reading Behavior
• Reading Mode
Sets the reading mode.
Default
: Single
Setting range : Single, Multi1, Multi2, or Burst read
• Data Transmission
Sets the timing to send data.
Default
: Send after read
Setting range : Send after read or Send after timing off
• Duplicate reading prevention interval (x100 ms)
Sets the time to prevent reading the same code twice in the Multi1 Reading
mode.
Default
: 1000 ms
Setting range : 100 to 25500 ms (in units of 100 ms)
• Duplicate reading prevention interval reset
Sets the duplicate reading prevention interval reset.
Default
: Reset when a code is read
Setting range : Reset when a code is read or Do not reset during duplicate
prevention interval
• Laser-Aim Pulse Duration.
Sets when Multi1 read mode or Multi2 read mode is specified.
Default
: 100 ms
Setting range : 0 to 990 ms (Specify by the 10 ms)
• Read error string
Sets the reading error code.
Default
: 4552524F52 (hexadecimal display, ASCII characters "ERROR")
Setting range : Enter a string using 8 or less ASCII or hexadecimal characters as
desired.
SOH (0x01)
SO (0x0e)
EM (0x19)
STX (0x02)
SI (0x0f)
SUB (0x1a)
ETX (0x03)
DLE (0x10)
FS (0x1c)
EOT (0x04)
DC1 (0x11)
GS (0x1d)
ENQ (0x05)
DC2 (0x12)
RS (0x1e)
BEL (0x07)
DC3 (0x13)
US (0x1f)
BS (0x08)
DC4 (0x14)
* If STX (0x02) or ETX (0x03) is set for
either the timing ON or OFF
command, the command is not
recognized in the "
HT (0x09)
SYN (0x16)
VT (0x0b)
ETB (0x17)
FF (0x0c)
CAN (0x18)
• Burst interval (x1 ms)
Sets the burst interval.
Default
: 0 ms
Setting range : 0 to 255 ms
• Burst count
Sets the number of scans in the burst read mode.
Default
: 3
Setting range : 1 to 8
• Burst bank
Sets the bank used in the burst read mode.
Default
: Bank 1
Setting range : Bank 1 to Bank 10
Master/Slave
• Operation setting
Sets the Master/Slave function operation.
Default
: Not used
Setting range : Not used, Multi Drop or Multi Head
• Group name
Sets group name.
Default
: GROUP01
Setting range : Input up to 16 arbitrary characters using the ASCII character.
• Unit ID
Sets ID of SR-750.
Default
: 0
Setting range : 0 to 31
• Read data number for Multi Head mode
Sets the number of read data during multi head operation.
Default
: 1
Setting range : 1 to 8
Alternate
• Priority bank
Sets the parameter bank to start reading when the Alternate function is used.
Default
: 1
Setting range : 1 to 10
• Order
Sets the alternate order changing method. When "Begin with successful bank" is
set, the alternate comes from the parameter bank that was last read successfully.
Default
: Begin with successfully read bank
Setting range : Sequential or Begin with successfully read bank
Matching Function
• Matching level OK/NG judgment
Sets to judge the matching level when a reading was successful.
Default
: Disable
Setting range : Disable or Enable
• Matching level threshold
Sets the threshold for matching level OK/NG judgment.
Default
: 70
Setting range : 0 to 99
Code quality verification
• ISO/IEC15415 verification
Sets ISO/IEC15415 verification function.
Default
: Disable
Setting range : Disable or Enable
• ISO/IEC15415 verification threshold
Sets the threshold of ISO/IEC15415 evaluation result.
Default
: Disable
Setting range : Disable, D, C, B or A
• ISO/IEC TR 29158 (AIM DPM-1-2006) verification
Sets ISO/IEC TR 29158 (AIM DPM-1-2006) verification function.
Default
: Disable
Setting range : Disable or Enable
• ISO/IEC TR 29158 (AIM DPM-1-2006) verification threshold
Sets the threshold of ISO/IEC TR 29158 (AIM DPM-1-2006) evaluation result.
Default
: Disable
Setting range : Disable, D, C, B or A