Operation – KEYENCE SR-750 Series User Manual

Page 45

background image

45

E SR-750 UM

Operation

„

TIMING

• Timing Mode

Sets the method of measuring timing.
Default

: Level trigger

Setting range : Level trigger or One-shot trigger

• One-shot trigger duration

Sets the measuring duration of one-shot trigger.
Default

: 1000 ms

Setting range : 30 to 25500 ms (in units of 10 ms)

• Timing ON command

Sets the timing ON command characters.
Default

: 4C4F4E (hexadecimal display, ASCII characters "LON")

Setting range : Enter a string using 8 or less ASCII or hexadecimal characters as

desired.

• Timing OFF command

Sets the timing OFF command characters.
Default

: 4C4F4646 (hexadecimal display, ASCII characters "LOFF")

Setting range : Enter a string using 8 or less ASCII or hexadecimal characters as

desired.

• One-character timing recognition

Set to enable one-character timing recognition.
Default

: Disable

Setting range : Disable or Enable

Important

The following strings can recognize a timing ON/OFF command as
one-character:

„

Reading Behavior

• Reading Mode

Sets the reading mode.
Default

: Single

Setting range : Single, Multi1, Multi2, or Burst read

• Data Transmission

Sets the timing to send data.
Default

: Send after read

Setting range : Send after read or Send after timing off

• Duplicate reading prevention interval (x100 ms)

Sets the time to prevent reading the same code twice in the Multi1 Reading
mode.
Default

: 1000 ms

Setting range : 100 to 25500 ms (in units of 100 ms)

• Duplicate reading prevention interval reset

Sets the duplicate reading prevention interval reset.
Default

: Reset when a code is read

Setting range : Reset when a code is read or Do not reset during duplicate

prevention interval

• Laser-Aim Pulse Duration.

Sets when Multi1 read mode or Multi2 read mode is specified.
Default

: 100 ms

Setting range : 0 to 990 ms (Specify by the 10 ms)

• Read error string

Sets the reading error code.
Default

: 4552524F52 (hexadecimal display, ASCII characters "ERROR")

Setting range : Enter a string using 8 or less ASCII or hexadecimal characters as

desired.

SOH (0x01)

SO (0x0e)

EM (0x19)

STX (0x02)

SI (0x0f)

SUB (0x1a)

ETX (0x03)

DLE (0x10)

FS (0x1c)

EOT (0x04)

DC1 (0x11)

GS (0x1d)

ENQ (0x05)

DC2 (0x12)

RS (0x1e)

BEL (0x07)

DC3 (0x13)

US (0x1f)

BS (0x08)

DC4 (0x14)

* If STX (0x02) or ETX (0x03) is set for

either the timing ON or OFF
command, the command is not
recognized in the " command
" format.

HT (0x09)

SYN (0x16)

VT (0x0b)

ETB (0x17)

FF (0x0c)

CAN (0x18)

• Burst interval (x1 ms)

Sets the burst interval.
Default

: 0 ms

Setting range : 0 to 255 ms

• Burst count

Sets the number of scans in the burst read mode.
Default

: 3

Setting range : 1 to 8

• Burst bank

Sets the bank used in the burst read mode.
Default

: Bank 1

Setting range : Bank 1 to Bank 10

„

Master/Slave

• Operation setting

Sets the Master/Slave function operation.
Default

: Not used

Setting range : Not used, Multi Drop or Multi Head

• Group name

Sets group name.
Default

: GROUP01

Setting range : Input up to 16 arbitrary characters using the ASCII character.

• Unit ID

Sets ID of SR-750.
Default

: 0

Setting range : 0 to 31

• Read data number for Multi Head mode

Sets the number of read data during multi head operation.
Default

: 1

Setting range : 1 to 8

„

Alternate

• Priority bank

Sets the parameter bank to start reading when the Alternate function is used.
Default

: 1

Setting range : 1 to 10

• Order

Sets the alternate order changing method. When "Begin with successful bank" is
set, the alternate comes from the parameter bank that was last read successfully.
Default

: Begin with successfully read bank

Setting range : Sequential or Begin with successfully read bank

„

Matching Function

• Matching level OK/NG judgment

Sets to judge the matching level when a reading was successful.
Default

: Disable

Setting range : Disable or Enable

• Matching level threshold

Sets the threshold for matching level OK/NG judgment.
Default

: 70

Setting range : 0 to 99

„

Code quality verification

• ISO/IEC15415 verification

Sets ISO/IEC15415 verification function.
Default

: Disable

Setting range : Disable or Enable

• ISO/IEC15415 verification threshold

Sets the threshold of ISO/IEC15415 evaluation result.
Default

: Disable

Setting range : Disable, D, C, B or A

• ISO/IEC TR 29158 (AIM DPM-1-2006) verification

Sets ISO/IEC TR 29158 (AIM DPM-1-2006) verification function.
Default

: Disable

Setting range : Disable or Enable

• ISO/IEC TR 29158 (AIM DPM-1-2006) verification threshold

Sets the threshold of ISO/IEC TR 29158 (AIM DPM-1-2006) evaluation result.
Default

: Disable

Setting range : Disable, D, C, B or A