[Communication2] tab

Set communications in line with the control host that connects the SR-750 Series
unit. These can be set or changedin the [Table] tab.

(1) : Command port

Select the interface to perform command communication. Commands
indicate operation and configuration commands.
Default

: RS-232C

Setting range : Not used, RS-232C or Ethernet

* If the Data port 2 interface is RS-232C, RS-232C cannot be

selected for the command communication.

* When Ethernet is selected, set the port number to receive

the SR-750 Series commands.
Port default: 9004

(2) : Data port 1

Select the interface to output the read data.
Default

: RS-232C

Setting range : Not used, RS-232C or Ethernet

* If the Data port 2 interface is RS-232C, RS-232C cannot be

selected for Data port 1.

* When Ethernet is selected, set the port number to receive

the SR-750 Series commands.
Port default: 9004

* When Ethernet is selected and the SR-750 is set as a

client, click the "Connected device settings" button to enter
the IP address and port number of the destination to send
the read data.

(3) : Data port 2

Select the interface and protocol to output the read data to a PLC.
• Interface

Default

: Not used

Setting range : Not used, RS-232C or Ethernet

* When Ethernet is selected, enter the IP address and port

number of the destination to send the read data.

• Protocol

Default

: MC protocol

Setting range : MC protocol, SYSWAY (only when RS-232C is selected),

KV STUDIO, Ethernet/IP (only when Ethernet is selected),
PROFINET (only when Ethernet is selected) or All-purpose
(No procedure/TCP)

• Memory layout

When the protocol is MC protocol, SYSWAY, or KV STUDIO, set the
memory layout.
• DM front address

Default

: 0

Setting range :

Page 82

• Control region address

Default

: 0

Setting range :

Page 82

• Response region address

Default

: 0

Setting range :

Page 82

(1)

(2)

(3)

(4)

• Ethernet/IP settings

Set Ethernet/IP.

• PROFINET settings: Details

Set PROFINET.

Important

EtherNet/IP and PROFINET communication cannot be used in
combination with the Master/Slave function.
If the Master/Slave function has already been selected, the
following message will appear. When setting EtherNet/IP and
PROFINET communication, set the Master/Slave function to "Not
used".

(4) : Format

• Header/Terminator

Sets the header and terminator of the read data.
• Header

Default

: None

Setting range : Select None, STX, ESC, or Config.

When Config is selected, enter the header using 5 or less
ASCII or hexadecimal characters as desired.

• Terminator

Default

: CR

Setting range : CR, CR+LF, ETX, or Config.

When Config is selected, enter the header using 5 or less
ASCII or hexadecimal characters as desired.

• Partition mark

The selected character is used as a separator in send data. Select any
single ASCII or hexadecimal character.
Default

: ":" (3Ah)

• Inter delimiter

The selected character is used as a separator for appended data. Select
any single ASCII or hexadecimal character.
Default

: "," (2Ch)