Communication2] tab – KEYENCE SR-750 Series User Manual
Page 40
40
E SR-750 UM
[Communication2] tab
Set communications in line with the control host that connects the SR-750 Series
unit. These can be set or changedin the [Table] tab.
(1) : Command port
Select the interface to perform command communication. Commands
indicate operation and configuration commands.
Default
: RS-232C
Setting range : Not used, RS-232C or Ethernet
* If the Data port 2 interface is RS-232C, RS-232C cannot be
selected for the command communication.
* When Ethernet is selected, set the port number to receive
the SR-750 Series commands.
Port default: 9004
(2) : Data port 1
Select the interface to output the read data.
Default
: RS-232C
Setting range : Not used, RS-232C or Ethernet
* If the Data port 2 interface is RS-232C, RS-232C cannot be
selected for Data port 1.
* When Ethernet is selected, set the port number to receive
the SR-750 Series commands.
Port default: 9004
* When Ethernet is selected and the SR-750 is set as a
client, click the "Connected device settings" button to enter
the IP address and port number of the destination to send
the read data.
(3) : Data port 2
Select the interface and protocol to output the read data to a PLC.
• Interface
Default
: Not used
Setting range : Not used, RS-232C or Ethernet
* When Ethernet is selected, enter the IP address and port
number of the destination to send the read data.
• Protocol
Default
: MC protocol
Setting range : MC protocol, SYSWAY (only when RS-232C is selected),
KV STUDIO, Ethernet/IP (only when Ethernet is selected),
PROFINET (only when Ethernet is selected) or All-purpose
(No procedure/TCP)
• Memory layout
When the protocol is MC protocol, SYSWAY, or KV STUDIO, set the
memory layout.
• DM front address
Default
: 0
Setting range :
Page 82
• Control region address
Default
: 0
Setting range :
Page 82
• Response region address
Default
: 0
Setting range :
Page 82
(1)
(2)
(3)
(4)
• Ethernet/IP settings
Set Ethernet/IP.
• PROFINET settings: Details
Set PROFINET.
Important
EtherNet/IP and PROFINET communication cannot be used in
combination with the Master/Slave function.
If the Master/Slave function has already been selected, the
following message will appear. When setting EtherNet/IP and
PROFINET communication, set the Master/Slave function to "Not
used".
(4) : Format
• Header/Terminator
Sets the header and terminator of the read data.
• Header
Default
: None
Setting range : Select None, STX, ESC, or Config.
When Config is selected, enter the header using 5 or less
ASCII or hexadecimal characters as desired.
• Terminator
Default
: CR
Setting range : CR, CR+LF, ETX, or Config.
When Config is selected, enter the header using 5 or less
ASCII or hexadecimal characters as desired.
• Partition mark
The selected character is used as a separator in send data. Select any
single ASCII or hexadecimal character.
Default
: ":" (3Ah)
• Inter delimiter
The selected character is used as a separator for appended data. Select
any single ASCII or hexadecimal character.
Default
: "," (2Ch)