I/o] tab, Saving images] tab, Edit data – KEYENCE SR-750 Series User Manual
Page 42
42
E SR-750 UM
Edit data
(1) Additional Information
Checking the checkbox of data to add can set the Additional Information.
Default
: None for all items
(2) Read Data Format
Displays the position of added data when the Additional Information is set.
(3) Edit Data
Check "Use script" when using the edit data function.
[I/O] tab
Set operations for input/output terminals. These can be set or changed in the
[Table] tab.
Input Terminal
Set the operation of the input terminals (IN1 and IN2).
(1) Input Polarity
Specify the polarity of the input terminal.
Default
: Norm. open
Setting range : Norm. open (normally open) or Norm. close (normally closed)
(2) Required Input Duration
Set the time delay before the input terminal turns on.
Default
: 1 ms
Setting range : 1 ms, 2 ms, 10 ms
(3) IN1, IN2 Function
• Function
IN1 default
: TIMING
IN2 default
: PRESET
Settings range : TIMING, Preset Input, TEST, Clear PLC link error, TUNING,
Disable
• Test mode
When you select "TEST", specify the test mode desired.
Settings range : reading rate test, processing time test, position test
• Power-ON trigger
Select this to activate IN1 and IN2 specified at power-on.
(1)
(2)
(3)
(1)
(2)
(4)
(3)
(5)
Output terminal
Set the functions of the output terminals (OUT1, OUT2, OUT3).
(4) OUT1, OUT2, OUT3 terminal functions
• Terminal function
OUT1 default : OK
OUT2 default : NG+ERROR
OUT3 default : TRG BUSY, LOCK BUSY, MODE BUSY, ERR BUSY
Setting range : OK, NG, ERROR, STABLE, UNSTABLE, PRESET OK,
TUNING OK, TRG BUSY, LOCK BUSY, MODE BUSY, ERR
BUSY
EXT. LIGHT
• EXT. LIGHT
Select to use external lighting.
Select this to make the [EXT. LIGHT] button active.
(5) • Output Duration
Specify the polarity of the output terminal. (Common between terminals)
Default
: 500 ms
Setting range : 0 to 2550 ms (Specify in units of 10 ms)
• TRG BUSY at Power-On
Specify start-up options when TRG BUSY is set.
Default
: Disable
Setting range : Disable, Enable
Refer to
"3-6 Multi-I/O Function (Page 14)"
[Saving Images] tab
Set functions for saving images. These can be set or changed in the [Table] tab.
Image saving function settings
Set image saving functions and modes.
(1) Saving images operations
Default
OK Image
: Disable
NG Image
: Disable
Error Image
: Save to RAM
Unstable image
: Disable
Captured Image : Save to RAM
Setting range OK Image/NG Image/Unstable image
: Disable, Send by FTP
Error Image
: Disable, Save to RAM, Save to ROM,
Send by FTP
Captured Image : Save to ROM, Send by FTP
If burst read mode is set as the operating mode, specify the burst number for
the target images.
NOTICE
You cannot set the result outputs (OK, NG, ERROR, PRESET OK,
TUNING OK), and the operation outputs (TRG BUSY, LOCK BUSY,
MODE BUSY, ERR BUSY) to the same output terminal.
• External lighting output polarity
Default
: Norm. open
Setting range : Norm. open (normally
open) or Norm. close
(normally closed)
(2)
(4)
(3)
(1)