beautypg.com

Communication configuration command format (wn/rn), Tuning settings – KEYENCE SR-750 Series User Manual

Page 81

background image

81

E SR-750 UM

„

Tuning settings

Communication Configuration Command Format (WN/RN)

Communication configuration command is sent in the following format:
• Configuration change

Send command

Response

Normal process

Abnormal process

• Configuration confirmation

Send command

Response

Normal process

Abnormal process

mmm : Command number Fixed to 3 bytes
nnn… : Setting value (varies according to command number)

example: Changing SR-750 Series IP address to "192.168.100.1"

Configuration change

Send command

WN, 200, 192.168.100.1

Response (Normal process) OK, WN

Configuration confirmation Send command

RN, 200

Response (Normal process) OK, RN, 192.168.100.1

Important

To change and apply the communication configuration, make sure
to send a SAVE command.

Function

Command

Number

Setting

value

Explanation

Default

Brightness adjustment
mode

801

0, 1

0 : High quality mode
1 : High speed mode

1

Exposure on high
speed mode

802

3 to 333

Exposure time = setting value ×
30

μs

0005

Offset setting

803

000 to
255

Use the default value of 255 for
normal use.

255

Dynamic range setting

804

0, 1

0 : Hi-Sensitive/Hi-SNR
1 : Hi-DR

0

Tuning mode

805

0, 1

0 : Normal Mode
1 : Filter

0

Codes to read while
tuning

808

01 to 16

1

Allow reduced detection
count while tuning

809

0, 1

0 : Do not allow
1 : Allow

0

Tuning target code

820

1 to
00773

1 : QR
2 : DataMatrix

10 : GS1 DataBar
20 : CODE39
40 : ITF

100 : NW-7 (Codabar)
200 : JAN/EAN/UPC
400 : CODE128

Specify the setting using sum of
each item.

00773

Black-white reverse
read setting when
tuning

823

0 to 2

0 : Disable
1 : Enable
2 : Automatic

2

Internal lighting when
tuning

821

0, 1

0 : Not used
1 : Used

1

External lighting when
tuning

822

0, 1

0 : Not used
1 : Used

0

WN

, mmm ,

nnn…

OK

,

WN

ER

,

WN

,

ee

ee: Error code

RN

, mmm

OK

,

RN

,

nnn…

ER

,

RN

,

ee

ee: Error code

„

Communication port settings

„

RS-232C communication settings

„

Ethernet communication settings

Function

Command

Number

Setting

value

Explanation

Default

Command port
configuration

000

0 to 2

0 : Not used
1 : RS232C
2 : Ethernet

1

Data port 1
configuration

001

0 to 2

0 : Not used
1 : RS232C
2 : Ethernet

1

Data port 2
configuration

002

0 to 2

0 : Not used
1 : Reserve
2 : Ethernet

2

Append checksum

003

0, 1

0 : Disable
1 : Enable

0

Append data size

004

0, 1

0 : Disable
1 : Enable

0

Header settings

005

hhhh···

Specify up to 5 characters (16 HEX
bytes) from HEX (0x00 to 0x7F).
FF : Not set

FF

Terminator settings

006

hhhh···

Specify up to 5 characters (16 HEX
bytes) from HEX (0x00 to 0x7F).
FF : Not set

0D

Function

Command

Number

Setting

value

Explanation

Default

Baud rate setting

100

0 to 4

0 : 9600bps
1 : 19200bps
2 : 38400bps
3 : 57600bps
4 : 115200bps

4

Data length setting

101

0, 1

0 : 7bit
1 : 8bit

1

Parity check setting

102

0 to 2

0 : Disable
1 : Even
2 : Odd

1

Stop bit length setting

103

0, 1

0 : 1bit
1 : 2bit

0

Communication
protocol setting

104

0 to 2

0 : No Handshaking
1 : PASS/RTRY
2 : ACK/NAK

0

Function

Command

Number

Setting

value

Explanation

Default

IP address setting

200

a. b. c. d

a : 0 to 255
b : 0 to 255

c : 0 to 255

d : 0 to 255

192.168.

100.100

Subnet mask setting

201

8 to 30

Specify with bit length
255.255.255.0 ···24
255.0.0.0

···8

24

Default gateway setting

202

a. b. c. d

a : 0 to 255
b : 0 to 255

c : 0 to 255

d : 0 to 255

0.0.0.0

(Not set)

IP address setting at
connection destination

203

a. b. c. d

a : 0 to 255
b : 0 to 255

c : 0 to 255

d : 0 to 255

0.0.0.0

(Not set)

Port number setting for
connection destination

204

1024 to
65535

9004

Setting of connection
establishment request
transmission

205

0, 1

0 : Disable
1 : Enable

0

Port number setting for
Data port 1

206

1024 to
65535

Unavailable: 9013, 9014, 9015,
9016, 5920, 44818

9004

Port number setting for
command port

207

1024 to
65535

Unavailable: 9013, 9014, 9015,
9016, 5920, 44818

9004

Keep/Alive function
setting for Data port 1

208

0, 1

0 : Not use
1 : Enable

1

Command port Keep/
Alive function setting

209

0, 1

0 : Not use
1 : Enable

1

* Set when used

as a client