Word area and byte area, E sr-750 um – KEYENCE SR-750 Series User Manual
Page 110
110
E SR-750 UM
2 1 byte
BUSY Status
Bits
0 BUSY
OR of each BUSY
signal
0 : No BUSY status
1 : BUSY status
1 TRG BUSY
Main unit in TRG
BUSY status
0 : No TRG BUSY
status
1 : TRG BUSY status
2 LOCK BUSY
Main unit in LOCK
BUSY status
0 : No LOCK BUSY
status
1 : LOCK BUSY
status
3 MODE BUSY
Main unit in MODE
BUSY status
0 : No MODE BUSY
status
1 : MODE BUSY
status
4 ERR BUSY
Main unit in ERR
BUSY status
0 : No ERR BUSY
status
1 : ERR BUSY status
Cancellation is
required.
5 FILE BUSY
Main unit in FILE
BUSY status
0 : No FILE BUSY
status
1 : FILE BUSY status
6 (Reserved)
Reserved area
7 (Reserved)
Reserved area
3 1 byte
Completion
Status Bits
0 Read Complete
Read operation
completion
notification
0 : Incomplete
1 : Complete
This is cleared at the
start of Clear Bit in
each status or at the
start of the next
operation.
1 Preset Complete
Preset read
completion
notification
0 : Incomplete
1 : Complete
2
Register Preset
Data Complete
Preset data
registration
completion
notification
0 : Incomplete
1 : Complete
3 Tune Complete
Tuning completion
notification
0 : Incomplete
1 : Complete
4 (Reserved)
Reserved area
5 (Reserved)
Reserved area
6 (Reserved)
Reserved area
7
EXT. Request
Complete
External instruction
operation completion
notification
0 : Incomplete
1 : Complete
1 is output when
"Reading", "Preset
reading" and "Tuning"
are performed via
external terminals or
commands and
results are obtained.
4 1 byte
Error Status
Bits
0 Read Failure
Reading error
notification
0 : -
1 : Reading error
The cause of failure
can be checked with
Read Result Code.
This is cleared at the
start of Read
Complete Clear Bit or
at the start of the next
operation.
1 Preset Failure
Preset reading error
notification
0 : -
1 : Preset reading
Error
The cause of failure
can be checked with
Preset Result Code.
This is cleared at the
start of Preset
Complete Clear Bit or
at the start of the next
operation.
2
Register Preset
Data Failure
Preset data
registration failure
notification
0 : -
1 : Preset data
registration failure
The cause of failure
can be checked with
Preset Data Result
Code.
This is cleared at the
start of Register
Preset Data
Complete Clear Bit or
at the start of the next
operation.
3 Tune Failure
Tuning failure
notification
0 : -
1 : Tuning failure
The cause of failure
can be checked with
Tune Result Code.
This is cleared at the
start of Tune
Complete Clear Bit or
at the start of the next
operation.
4 (Reserved)
Reserved area
5 (Reserved)
Reserved area
6 (Reserved)
Reserved area
7
EXT. Request
Failure
External instruction
operation failure
notification
0 : -
1 : External
instruction
operation failure
1 is output when
"Reading", "Preset
reading" and "Tuning"
are performed via
external terminals or
commands and the
operation fails. The
cause of failure can
be checked with
EXT.Request Result
Code.
This is cleared at the
start of EXT. Request
Complete Clear Bit or
at the start of the next
operation.
5 1 byte
Terminal
Status Bits
0 IN1 Status
Input terminal 1
status
0 : OFF
1 : ON
1 IN2 Status
Input terminal 2
status
0 : OFF
1 : ON
2 (Reserved)
Reserved area
3 (Reserved)
Reserved area
4 OUT1 Status
Output terminal 1
status
0 : OFF
1 : ON
5 OUT2 Status
Output terminal 2
status
0 : OFF
1 : ON
6 OUT3 Status
Output terminal 3
status
0 : OFF
1 : ON
7 (Reserved)
Slot
Size
Module
name
Bit
address
Name
Description
Data contents
Remarks
Word area and byte area
In the following areas, information is represented with the following units.
• Word areas : Areas where 0 to 65535 is represented as a 2-byte unsigned
integer
• Byte area
: Areas where a character code such as ASCII code is represented
6 1 byte
Unstable
Read Status
Bits
0 Unstable
Unstable reading
status
OR of each Unstable
0 : Stable
1 : Unstable
1
Matching Level
Unstable
Matching level
judgment result
unstable
0 : Stable
1 : Unstable
2
ISO/IEC 15415
Unstable
ISO/IEC 15415
verification result
unstable
0 : Stable
1 : Unstable
3
AIM DPM
Unstable
ISO/IEC TR 29158
(AIM DPM)
verification result
unstable
0 : Stable
1 : Unstable
4
SAE AS9132
Unstable
SAE AS9132
verification result
unstable
0 : Stable
1 : Unstable
5 (Reserved)
Reserved area
6 (Reserved)
Reserved area
7 (Reserved)
Reserved area
Slot
Size
Module
name
Representation
method
Name
Description
Data contents
Remarks
7 8 byte
Matching
Level and
Total
Evaluation
Grade Status
Word
Matching Level
Matching level
100 to 0
If multiple codes are
read, the smallest
value is displayed.
Word
ISO/IEC15415
Grade
ISO/IEC15415 total
evaluation grade
4 : A
3 : B
2 : C
1 : D
0 : F
Word
AIM DPM Grade
ISO/IEC TR 29158
(AIM DPM) total
evaluation grade
4 : A
3 : B
2 : C
1 : D
0 : F
Word
(Reserved)
Reserved area
8 20 byte
Operation
Result Status
Word
Read Result Code
Reading operation
result code
Error code
Refer to List of error
codes.
Word
Preset Result
Code
Preset data read
result code
Error code
Word
Register Preset
Data Result Code
Preset data
registration result
code
Error code
Word
Tune Result Code
Tuning operation
result code
Error code
Word
(Reserved)
Reserved area
Word
(Reserved)
Reserved area
Word
(Reserved)
Reserved area
Word
EXT. Request
Result Code
External instruction
operation result code
Error code
Refer to List of error
codes.
Word
General Error
Code
General error code
Error code
Word
(Reserved)
Reserved area
9
8 +
(data
size)
byte
• Read Data
32Byte
• Read Data
64Byte
• Read Data
128Byte
• Read Data
246Byte
* Select one
of them.
Word
Result Data Ready
Count
Result data reception
count
The number returns
to 0 if it exceeds
65535.
Word
Result Data
Update Count
Result data update
count
Word
(Reserved)
Reserved area
Word
Result Data Size
Result data size
(byte)
• 32
bytes
• 64
bytes
• 128
bytes
• 246
bytes
Result Data
Result data output
(Array of bytes)
Result data output
• When append data
has been set, the
append data is
output.
• When the silent
mode is set, this
area is not
updated.
• NULL (0x00) is
appended after
result data.
Slot
Size
Module
name
Bit
address
Name
Description
Data contents
Remarks