Page 87: Configuring the sysmac series rs-232c interface, Assignment of control region functions, Assignment of response region functions, Cpu built-in port, Serial communication unit/board

background image

87

E SR-750 UM

Configuring the SYSMAC Series

RS-232C Interface

Set communication conditions with the CX-Programmer.

„

CPU built-in port

PLC system configuration

→Upper link port (serial port)

* When communication configuration is established as a standard, baud rate and

parameters are fixed as above.

„

Serial communication unit/board

CJ1W-SCU□□(-V1)
CS1W-SCU□□-V1
CS1-SUB□□-V1
I/O table/unit configuration

Communication
configuration

User configuration

Baud rate

9600 bits/s

Parameter

7,2,E

Mode

Upper link

ID No.

0

Presence or absence of
optional configuration

Optional configuration

Communication mode

Upper link

Data length

7 bits

Stop bit

2 bits

Parity

Even

Transmission rate

9600 bps

CTS control

None

Upper link ID No

0

9-3

Device Assignment

To use the SR-750 Series over the PLC link, functions of the SR-750 Series need
to be assigned to the PLC devices.
For the SR-750 Series, the first address of each device is assigned in response to
target function.

• Control region

: Device used to write a command from the PLC. One channel

is used for device assignment.

• Response region : Device used to write a response from the SR-750 Series.

One channel is used for device assignment.

• Data region

: Device used to write alternate instructions of the SR-750

Series and result data from the SR-750 Series. Occupies a
maximum of 54 devices with serial numbers.

Function Assignment of Control Region, Response Region, and Data Region

This section describes assignment of functions of each region.

Assignment of Control Region Functions

When the control region address A is specified, functions are assigned in order as
shown below starting with the specified beginning address.

* When performing the trigger input ON/OFF using the PLC timing area, set "PLC

link timing input" to "Enable".

Assignment of Response Region Functions

When the response region address B is specified, functions are assigned in order
as shown below starting with the specified beginning address.

* Do not use the reserved area.

A15 A14 A13 A12 A11 A10 A09 A08 A07 A06 A05 A04 A03 A02 A01 A00

Reserved area

Address

Description

Data description

SR-750

Write

PLC Write

A00

PLC timing area

0:Instruction for timing OFF
1: Instruction for timing ON

×

A01

Data write processing
method

0: Real time processing
1: Sequential processing

×

A02

Sequential processing
Data write enabled

0: Data write disabled
1: Data write enabled

×

B15 B14 B13 B12 B11 B10 B09 B08 B07 B06 B05 B04 B03 B02 B01 B00

Reserved area

Address

Description

Data description

SR-750

Write

PLC Write

B00

PLC timing input
response area

0: Timing OFF
1: Instruction for timing ON

×

B01

Reserved area

B02

Sequential processing
Data write request

0: No data
1: Data write request

×

B03

Sequential processing
Data write complete

0: Data write incomplete
1: Data write complete

×

B04

Real time processing
Data being written

0: No data being written
1: Data being written