85

E SR-750 UM

9-1

PLC Link

This chapter presents an overview and the control method of the PLC link.

PLC Link

The PLC link allows the SR-750 Series to directly write data into the internal
memory of the PLC (programmable logic controller) via the RS-232C interface and
Ethernet interface.
Since the SR-750 Series directly controls memory in the PLC, it eliminates the
need for a communication program. Therefore, man-hours needed to create
programs can be reduced.

Important

The following restrictions are imposed regarding the use of the
PLC link:
• The SR-750 configuration cannot be changed via PLC link.
• Test mode cannot be activated via PLC link.
• Operation command and setup command cannot be sent via

PLC link.

• Due to long communication time, it is not suitable for a line that

requires high-speed processing.

• The amount of data that can be processed depends on the

output data length. A maximum number of digits is 100.
(Default output data length is 64 digits.)

List of supported PLCs

RS-232C Interface

„

KEYENCE

„

Mitsubishi Electric

„

OMRON

* A serial option board is necessary, depending on the model.

Ethernet Interface

„

KEYENCE

„

Mitsubishi Electric

Series name

Connection method

Model

KV Series

CPU built-in port

KV-3000, KV Nano Series

Communication unit

KV-L20V/L20R,
KV-N10L/NC10L/NC20L

Series name

Connection method

Model

MELSEC Series

Serial communication unit

QJ71C24N/-R2
LJ71C24/-R2

Series name

Connection method

Model

SYSMAC Series

CPU built-in port

CS1 Series
CJ1 Series
CJ2 Series

*

CP1 Series

*

Serial option board

CP1W-CIF01
CP1W-CIF11
CP1W-CIF12

Serial communication unit

CJ1W-SCU□□(-V1)
CS1W-SCU□□-V1

Communication board

CS1-SUB□□-V1

Series name

Connection method

Model

KV Series

CPU built-in port

KV-5000/5500

Ethernet unit

KV-LE21V/LE20V, KV-NC1EP

Series name

Connection method

Model

MELSEC Series

CPU built-in port

Q03/04/06/10/13/20/26/50/
100UDECPU
L02CPU/06CPU/26CPU-BT

Ethernet unit

QJ71E71-100/-B5/-B2

Devices that can be used

Devices accessible via PLC link are as follows:

• The available range is a maximum value of the device accessible when the PLC

link function is used. To specify the DM front address, control region address, or
response region address, configure by taking into account the number of
necessary devices.

• The device region that can actually be used may not be configured up to a

maximum value or may include unavailable area, depending on specifications
and configuration. For more information on available regions, refer to the
appropriate PLC manual.

*1 AutoID Network Navigator entry field range:

to

*2 AutoID Network Navigator entry field range:

to

• Specifying the Control region address and the Response region address

Inputting

in the AutoID Network Navigator entry field means that the shaded

area as indicated below is specified.

9-2

Configuration

This section describes the configuration of the SR-750 Series and PLC.

SR-750 Series configuration

Configure the SR-750 Series using the AutoID Network Navigator as follows:

1

Set the interface to "RS-232C" or "Ethernet" under the PLC
communication in the Communication 2 tab.

• When the interface is set to "RS-232C", command communication and PC

host output interface configuration are switched to "Not used".

2

Select the protocol appropriate for the PLC to be used.

• Mitsubishi MELSEC Series

: MC Protocol

• OMRON SYSMAC Series

: SYSWAY

* RS-232C only

• KEYENCE KV Series

: KV STUDIO

3

-1

When the interface is set to RS-232C, set "Baud rate", "Data
length", "Stop bit length" to match the configuration in the PLC.

3

-2

When the interface is set to Ethernet, set "IP address" and "Port
number" in the PLC.

4

Set "PLC link timing input".

To perform read operation using A00: PLC timing area, set "PLC link timing
input" in the [Table] tab to "Enable".
To input the timing signal directly into the SR-750 Series, set it to "Disable".

5

Set "DM address", " Control region address", and "Response region
address".

"9-3 Device Assignment (Page 87)"

PLC

Specified area

Device name

Available range

KV Series

Control region

Input relay, output relay

R100 to R59915

*1

Response region
Data region

Data memory

DM0 to DM65534

MELSEC Series

Control region

Input device

Y0 to Y7FF

*2

Response region

Output device

X0 to X7FF

*2

Data region

Data register

0 to 32737

SYSMAC Series

Control region

CIO, internal auxiliary
relay

0 to 6143 ch

Response region
Data region

Data memory

D0000 to D9999

F

E

D

C

B

A

9

8

7

6

5

4

3

2

1

0

1
2

←Front address

3
4
5

1

599

0

7F

2