Saving images – KEYENCE SR-750 Series User Manual
Page 47
47
E SR-750 UM
I/O
Input Terminal Common
• Input polarity
Sets the input polarity of the IN terminal.
Default
: Norm. open
Setting range : Norm. open or Norm. close
• Required input duration
Sets the required input duration for the IN terminal.
Default
: 2 ms
Setting range : 1 ms, 2 ms, or 10 ms
IN1/2 Terminal
• Function
Sets the function for the IN1/2 terminal.
Default
: IN1 terminal…Timing input
IN2 terminal…Preset input
Setting range : Disable, TIMING, Preset Input, TEST, Clear PLC link error,
TUNING
• Test mode
When "TEST" is selected, specify the test mode to start.
Default
: Reading rate test
Setting range : Reading rate test, Read time test, or Positioning test
• Startup state
Sets whether to activate the input function specified for the IN1 and IN2 terminals
at power-on.
Default
: Disable
Setting range : Disable or Enable
• IN LED synchronization
Set whether to synchronize with IN LED.
Default
: IN1…Enable
IN2…Disabled
Setting range : Disable or Enable
Output Terminal
• TRG BUSY Output at Power On
Set this option to enable TRG BUSY output upon reader startup.
Default
: Enable
Setting range : Disable or Enable
• Output duration
Sets the output ON duration for the OUT terminal.
Default
: 500 ms
Setting range : 10 to 2550 ms
• OUT1/2/3 function
Sets the function for the OUT1/2/3 terminal.
Default
OUT1…OK
OUT2…NG (Comparison NG), ERROR
OUT3…TRG, LOCK, MODE, ERR BUSY
Setting range : OK, NG (Comparison NG), ERROR, STABLE, UNSTABLE,
PRESET OK, TUNING OK, TRG BUSY, LOCK BUSY, MODE
BUSY, ERR BUSY, FILE BUSY or EXT.LIGHT
• External light output polarity
Sets the output polarity of the EXT.LIGHT signal.
Default
: Norm. open
Setting range : Norm. open, Norm. closed
Saving Images
• OK image
Sets the saving option for images successfully read.
Default
: Disabled
Setting range : Disabled or Send by FTP
• Comparison NG
Set save destination for comparison NG image.
Default
: Disable
Setting range : Disabled or Send by FTP
• Error image
Sets the save destination for read error images.
Default
: Save to RAM
Setting range : Disabled, Save to RAM, Save to ROM, or Send by FTP
• Unstable image
Sets the save destination for unstable images.
Default
: Disable
Setting range : Disabled or Send by FTP
• Target burst number
Default
: All banks
• Captured image
Sets the saving option for captured images.
Default
: Save to RAM
Setting range : Save to RAM or Send by FTP
• Image Save Mode
Sets the image saving mode.
Default
: Save final bank image
Setting range : Save final bank image, Save specified number of images after
timing ON, or Save specified number of images after timing OFF
• Number of images to save
Sets the number of images to save after the timing ON/OFF.
Default
: 10 images
Setting range : 1 to 10 images
• Edit image file name by script (FTP transmission only)
Sets the edit image file name function.
Default
: Disable
Setting range : Disable or Enable
FTP Settings
• IP address
Sets the IP address of the remote FTP server.
Default
: 0.0.0.0
Setting range : 0.0.0.0 to 255.255.255.255
• User/Password
Sets the user name/password of the destination required for FTP client
operations.
Default
: User…admin
Password…admin
Setting range : Up to 16 characters
Set in ASCII characters.
• Passive mode
Set this option to send passive commands to the remote FTP server.
Default
: Disable
Setting range : Enable or Disable
• Change directory
Set this option to change FTP remote directory.
Default
: Disabled
Setting range : Disable or Enable
• Format
Sets the image format sent via FTP.
Default
: JPEG
Setting range: JPEG, Bitmap
• JPEG quality
Default
: 5
Setting range : 1 to 10
• Binning
Default
: 1/4
Setting range: Full, 1/4, 1/16, 1/64
• Directory name
Sets the remote directory.
Default
: image
Setting range : 1 to 32 characters