• Connection request

Sets whether the reader sends connection requests for PC host output. *Only
when the interface is set to Ethernet
Default

: Disabled

Setting range : Disable or Enable

• Port (Waiting)

Sets the port number for PC host output of the SR-750 Series. *Only when the
interface is set to Ethernet
Default

: 9004

Setting range : 1024 to 655355

* 9013, 9014, 9015, 9016, 5900, 5910, and 44818 cannot be

used as they are reserved for the main unit system.

• Keep Alive

Sets the keep-alive function of PC host output. *Only when the interface is set to
Ethernet
Default

: Enable

Setting range : Enable or Disable

„

Data port 2

• Interface

Sets the interface to perform PLC communication.
Default

: Not used

Setting range : Not used, RS-232C, Ethernet

• Remote IP address

Sets the IP address of the remote PLC. *Only when the interface is set to
Ethernet
Default

: 0.0.0.0

Setting range : 0.0.0.0 to 255.255.255.25

• Remote port

Sets the port number of the remote PLC. *Only when the interface is set to
Ethernet
Default

: 5000

Setting range : 1024 to 65535

„

PLC link

• Protocol

Sets the PLC communication protocol.
Default

: MC protocol

Setting range : MC protocol, SYSWAY (*RS-232C only), KV STUDIO, None (*RS-

232C only), TCP (*Ethernet only), EtherNet/IP (*Ethernet only) or
PROFINET (only when Ethernet is selected)

• DM front address

Sets the DM front address when a PLC link is used.
Default

: 0

Setting range : MC protocol …0 to 32767

SYSWAY

…0 to 9999

KV STUDIO …0 to 65534

• Control region address

Sets the control region address when a PLC link is used.
Default

: 0

Setting range : MC protocol …0 to 7F

SYSWAY

…0 to 6143

KV STUDIO …1 to 599

• Response region address

Sets the response region address when a PLC link is used.
Default

: 0

Setting range : MC protocol …0 to 7F

SYSWAY

…0 to 6143

KV STUDIO …1 to 599

• PLC link timing input

Sets to enable timing input by PLC link.
Default

: Disabled

Setting range : Disable or Enable

• Output length

Sets the data write length by PLC link.
Default

: 64 digits

Setting range : 1 to 100 digits

• Timing/Data wait (x 100 ms)

Sets the communication interval of reading or writing to a PLC via PLC link.
Default

: 100 ms

Setting range : 0 to 9900 ms (in units of 100 ms)

• Retry duration

Sets the interval to reconnect when PLC link communication is disabled.
Default

: 5 seconds

Setting range : 1 to 30 seconds

„

EtherNet/IP

• Data handshake

Sets EtherNet/IP data handshake
Default

: Disable

Setting range : Disable or Enable

• Input assembly data size (send)

Sets EtherNet/IP Input assembly (send) size within the range from 40 to 1400.
Default

: 500

Setting range : 40 to 1400

• Output assembly data size (receive)

Sets EtherNet/IP Output assembly (receive) size within the range from 4 to 1400.
Default

: 500

Setting range : 4 to 1400

• Byte swapping

Sets EtherNet/IP Byte swap for the data area
Default

: Disable

Setting range : Disable or Enable

„

PROFINET

• Device name

Sets the device name used for PROFINET.
Default: sr-750

• Data handshake

Sets the data handshake.
Default

: Disable

Setting range : Disable or Enable

„

Format

• Header

Sets the header.
Default

: Not selected

Setting range : Enter the header using 5 or less ASCII or hexadecimal

characters as desired.

• Terminator

Sets the terminator.
Default

: 0D (hexadecimal display, ASCII characters [CR])

Setting range : Enter the header using 5 or less ASCII or hexadecimal

characters as desired.

• Partition mark

Sets the partition mark.
Default

: 3A (hexadecimal display, ASCII characters ":")

Setting range : Enter any single ASCII or hexadecimal character.

• Inter delimiter

Sets the inter delimiter.
Default

: 2C (hexadecimal display, ASCII characters ",")

Setting range : Enter any single ASCII or hexadecimal characters.

• Append data size

Set this option to append data size.
Default

: Disabled

Setting range : Disable or Enable

• Append checksum

Set this option to append checksum function.
Default

: Disabled

Setting range : Disable or Enable

Important

Device name rule
1. PROFINET device name length: 1 to 240 characters
2. 1 label length: 1 to 63 characters
3. Only [a to z] (alphabet lower case), [0 to 9] (numbers), [-]

(hyphen), [.] (period) can be used for a device name.

4. [-] (hyphen) cannot be used at the beginning of the label.
5. [-] (hyphen) cannot be used at the end of the label.
6. port-xyz, port-xyz-abcde cannot be the name of the first label.

a, b, c, d, e, x, y, z means [0 to 9] (numbers).

7. Device names cannot be made in the IP address format

(n.n.n.n n=0,…,999).

8. Labels cannot start with xn-.
9. The first character of labels cannot be a number.