1 sr-750 series specifications, General specifications, Reading range characteristics (typical) – KEYENCE SR-750 Series User Manual
Page 116: Sr-750 series specifications, Sr-750, Sr-751, Sr-752
116
E SR-750 UM
15-1
SR-750 Series Specifications
General Specifications
*1 Barcodes fitted into the visual field range in size can be read.
*2 The laser classification for FDA(CDRH) is implemented based on IEC60825-1
in accordance with the requirements of Laser Notice No.50.
*3 To comply with CSA No.61010-1/UL61010-1/IEC61010-1, use the following power supply.
The power supply that provides Class 2 output as defined in the CEC and NEC,
or the power supply that has been evaluated as a Limited Power Source as
defined in CAN/CSA-C22.2 No.60950-1/UL60950-1/IEC60950-1.
*4 Peak operating current for PoE Power Class 2: 210mA maximum.
Model
SR-750HA SR-750
SR-751
SR-752 SR-752+
SR-75L4
SR-752+
SR-75L6
Type
High
resolution
Close-
range
Mid-
range
Long-
range
400 mm lens
attached
600 mm lens
attached
Receiver
Sensor
CMOS Image Sensor
Number of pixels
752×480 pixels
Lighting Light source
Red LED
Laser
pointer
Light source
Visible semiconductor laser, Wavelength 660 nm
Output
60
μW
Pulse duration
200
μs
Laser class
Class 1 Laser Product
(IEC60825-1, FDA(CDRH) Part 1040.10
*2
)
Reading
specifications
Supported
symbol
2D
QR, MicroQR, DataMatrix (ECC200), GS1 DataMatrix,
PDF417, MicroPDF, Composite code (CC-A, CC-B, CC-C)
Barcode
*1
GS1 Databar, CODE39, CODE39 FullASCII, ITF,
NW-7 (Codabar), CODE128, GS1-128, JAN/EAN/UPC,
CODE93, 2of5(Industrial 2of5), COOP 2of5,
Trioptic CODE39
Minimum
resolution
2D
0.082 mm 0.127 mm 0.19 mm
0.19 mm
0.33 mm
0.5 mm
Barcode
-
0.127 mm 0.127 mm 0.17 mm
0.22 mm
0.33 mm
Reading
distance
(typical
examples)
DataMatrix
QR
22 to 50 mm
(Cell size=
0.25 mm)
40 to 80 mm
(Cell size=
0.25 mm)
45 to 165 mm
(Cell size=
0.5 mm)
180 to 305 mm
(Cell size=
0.5 mm)
300 to 490 mm
(Cell size=
0.5 mm)
460 to 690 mm
(Cell size=
0.5 mm)
Barcode
-
30 to 100 mm
(Narrow bar
width
= 0.33 mm)
45 to 195 mm
(Narrow bar
width
= 0.5 mm)
180 to 330 mm
(Narrow bar
width
= 0.5 mm)
250 to 540 mm
(Narrow bar
width
= 0.5 mm)
400 to 760 mm
(Narrow bar
width
= 0.5 mm)
Focal distance
38 mm
60 mm
100 mm 250 mm
400 mm 600 mm
Reading view range
(focal distance)
26.6 mm×
17.0 mm
42.5 mm×
27.1 mm
70.6 mm×
45.0 mm
65.0 mm×
41.5 mm
108 mm×
69 mm
165 mm×
106 mm
I/O
specifications
Control
input
Points
2
Input type
Bidirectional voltage input
Maximum
rating
26.4 VDC
Minimum
ON voltage
15 VDC
Maximum
OFF current
0.2 mA or less
Control
output
Points
3
Output type
Photo MOS relay output
Maximum
rating
30 VDC
Maximum
load current
1 output: 50 mA or less, 3 Total output 100 mA or less
Leakage
current
when OFF
0.1 mA or less
Residual
voltage
when ON
1 V or less
Ethernet
Communication
standard
10BASE-T/100BASE-TX
Supported
protocol
TCP/IP, SNTP, FTP, BOOTP, MC Protocol,
KVSTUDIO, EtherNet/IP, PROFINET
Serial
communication
Communication
standard
RS-232C compliant
Transmission
speed
9600, 19200, 38400, 57600, 115200 bps
Synchronization
method
Asynchronous
Supported
protocol
Non-procedure, MC Protocol, SYSWAY, KVSTUDIO
Environmental
resistance
Enclosure rating
IP65
Ambient
temperature
0 to 45°C
Ambient storage
temperature
-10 to +50°C
Relative humidity
35 to 95% RH (No condensation)
Storage ambient
humidity
35 to 95% RH (No condensation)
Ambient luminance
Sunlight: 10000lx, Incandescent lamp: 6000lx, Fluorescent lamp: 2000lx
Operating
environment
No dust or corrosive gas present
Vibration
10 to 55 Hz Double amplitude 1.5 mm/55 to 500 Hz: Acceleration 5G,
3 hours each in X, Y and Z directions
Rating
Power voltage
*3
Control port: 24 V DC ±10% or
Ethernet port: PoE TypeA/B 36 to 57 V (Cannot supply at the same time)
Current
consumption
Control port: 220mA or less (When 24 VDC power supply is used)
Ethernet port: PoE Power Class 2
*4
Weight
Approx. 160 g
Approx.
175 g
Approx. 185 g
Reading range characteristics (Typical)
Reading distance with cell sizes (narrow bar width) other than the chart below can
be confirmed using the introduction guide for AutoID Network Navigator.
Refer to
"5-12 Installation Guide (Page 53)"
SR-750
Unit: mm
SR-751
Unit: mm
SR-752
Unit: mm
Code type
Cell size
Narrow bar width
A
B
DataMatrix, QR
0.127
50
70
025
40
80
Code39
0.127
46
74
0.33
30
100
Code128
0.25
34
90
Code type
Cell size
Narrow bar width
A
B
DataMatrix, QR
0.25
65
130
0.5
45
165
Code39
0.127
75
110
0.5
45
195
Code128
0.25
50
150
Code type
Cell size
Narrow bar width
A
B
DataMatrix, QR
0.19
220
260
0.25
210
270
0.33
200
280
0.5
180
305
Code39
0.17
220
260
0.25
180
330
Code128
0.25
195
275
40
30
20
10
–20
–30
–40
0
–10
100
50
0
B
A
Focal distance = 60 mm
Unit: mm
80
60
40
20
–40
–60
–80
0
–20
100
150
200
50
0
B
A
Unit: mm
Focal distance = 100 mm
40
30
20
10
–20
–30
–40
0
–10
200
250
300
150
0
B
A
Unit: mm
Focal distance = 250 mm