1 checking the package contents, 2 part names and functions, Checking the package contents – KEYENCE SR-750 Series User Manual
Page 3: Part names and functions
3
E SR-750 UM
1-1
Checking the Package
Contents
The packages of the SR-750 Series main units and the SR-750 Series
configuration software contain the following components.
Check that you have all the package contents before use.
SR-750 Series (Fixed mount 2D code reader)
SR-H3W
Cable and connector
Main unit
SR-750/751/750HA
SR-752
Mounting bracket x 1
Mounting screw (M4) x 4
Port cover (Power supply and control port,
Ethernet connection port) x 1 each
Insulating spacer x 2
Washer x 2
Instruction Manual
AutoID Network Navigator
Control cable (Power supply, I/O, RS-232C)
• OP-87224 (2 m cable)
• OP-87225 (5 m cable)
• OP-87226 (10 m cable)
NFPA79 compliant Control cable
• OP-87353 (2 m cable)
• OP-87354 (5 m cable)
• OP-87355 (10 m cable)
Control cable (NFPA79-compliant) with D-Sub9 pin
(Power supply, I/O, RS-232C)
• OP-87527 (2 m cable)
• OP-87528 (5 m cable)
• OP-87529 (10 m cable)
1
E SR-750-IM
Fixed Mount 2D Code Reader
SR-750 Series
Instruction manual
Read this instruction manual before using the product in order to achieve
maximum performance.
Keep this instruction manual in a safe place after reading it so that it can be
used at any time.
Symbols
The following symbols alert you to important messages. Be sure to read
these messages carefully.
Important
It indicates cautions and limitations that must be followed during operation.
Point
It indicates additional information on proper operation.
Reference
It indicates tips for better understanding or useful information.
indicates the reference pages in this manual or the reference pages in separate manuals.
Safety Information for SR-750 Series
General Precautions
Safety precautions on Laser product
The SR-750 Series Fixed Mount 2D Code Reader uses a visible semiconductor
laser, with a wavelength of 660 nm, as a Laser pointer for adjusting the reading
position.
Laser Pointer Specifications
* The laser classification for FDA(CDRH) is implemented based on
IEC60825-1 in accordance with the requirements of Laser Notice No.50.
Precautions on Proper Use
Precautions on Regulations and Standards
CE Marking
Keyence Corporation has confirmed that this product complies with the
essential requirements of the applicable EC Directive, based on the
following specifications. Be sure to consider the following specifications
when using this product in the Member State of European Union.
z EMC Directive (2004/108/EC)
• Applicable standards
EMI : EN61326-1, Class A
EMS : EN61326-1
Remarks:
These specifications do not give any guarantee that the end-product with
this product incorporated complies with the essential requirements of
EMC Directive. The manufacturer of the end-product is solely responsible
for the compliance on the end-product itself according to EMC Directive.
z Low-voltage Directive (2006/95/EC)
• Applicable Standard
EN60825-1,
Class 1 Laser Product
EN62471
CSA Certificate
This product complies with the following CSA and UL standards and has
been certified by CSA.
• Applicable standards: CAN/CSA C22.2 No.61010-1
UL61010-1
Be sure to consider the following specifications when using this product as a
product certified by CSA.
• Overvoltage category
• Use this product under pollution degree 3.
• Use this product at the altitude of 2000 m or less.
• Indoor use only.
• When using this product, use the following power supply.
• CSA or UL certified power supply that provides Class 2 output as defined
in the CEC (Canadian Electrical Code) and NFPA79 (NEC: National
Electrical Code), or
• CSA or UL certified power supply that has been evaluated as a Limited
Power Source as defined in CAN/CSA-C22.2 No. 60950-1/UL60950-1.
• Either PoE or 24V power supply shall be used.
• The symbol
on the product means "Direct current".
FDA (CDRH) Regulations
This product complies with the following FDA (CDRH) regulations.
• FDA(CDRH) Part 1040.10, Class 1 Laser Product
The laser classification for FDA(CDRH) is implemented based on IEC60825-
1 in accordance with the requirements of Laser Notice No.50.
FCC Regulations
This product complies with the following FCC EMI regulations.
• FCC Part 15 Subpart B, Class A Digital Device
IC (Industry Canada) Regulations
This product complies with the following IC EMI regulations.
• ICES-003, Class A Digital Apparatus
It indicates a hazardous situation which, if not avoided, will result in death or
serious injury.
It indicates a hazardous situation which, if not avoided, could result in death
or serious injury.
It indicates a hazardous situation which, if not avoided, could result in minor
or moderate injury.
It indicates a situation which, if not avoided, could result in product damage
as well as property damage.
• Do not use this product for the purpose to protect a human body or a part
of human body.
• This product is not intended for use as explosion-proof product. Do not
use this product in a hazardous location and/or potentially explosive
atmosphere.
• Be sure to check that the SR-750 Series performs properly before starting
the work or operation.
• If the SR-750 Series malfunctions, take adequate safety precautions to
prevent various types of damage.
• Do not use the SR-750 Series in a manner not specified herein. It may
result in fire, electric shock or malfunction.
• It should be noted that functions and performances will not be guaranteed
if the SR-750 Series is used in any way not specified or described in the
product specifications or it is modified.
• When the SR-750 Series is used in combination with other devices,
functions and performance may be degraded, depending on the operating
conditions and environment.
Wavelength
660nm
Output
60
PW
Pulse duration
200
Ps
Laser class
Class 1 Laser Product
(IEC60825-1:2007, FDA(CDRH) Part 1040.10*)
• Use of controls or adjustments or performance of procedures other than
those specified herein may result in hazardous radiation exposure.
• Do not disassemble this product. The laser radiation emission from this
product is not automatically stopped when it is disassembled.
Precautions on Class 1 Laser Product
• Do not stare into the direct or specularly reflected beam.
96M12458
DANGER
WARNING
CAUTION
NOTICE
WARNING
CAUTION
NOTICE
WARNING
• Do not use a voltage other than that described in the specifications with
the SR-750 Series. Doing so may damage to the unit.
• The SR-750 Series employs 2 power connection methods, which are 24 V
DC supply and supply from PoE power supply devices. When connecting
the SR-750 Series to the power source, be sure to use only one of these
methods. Using both power sources simultaneously may cause damage
to the units.
• Be sure to turn off the power to devices attached to the SR-750 Series
when you plug in or unplug the cables.
Failure to do so may cause damage to the SR-750 Series.
• Do not disassemble or modify the SR-750 Series. Doing so may damage to
the unit.
• Place cables as far away as possible from high-voltage lines and power
lines. Otherwise, electrical noise can be generated that may cause product
failure or malfunction.
• The SR-750 Series is a precision instrument. Do not impact or drop the
instrument. Pay particular attention when transporting or installing the
unit.
• Do not hold the unit by its cable when carrying. The units may become
damaged if the cables are disconnected or the units strike each other.
• Do not allow water, oil, dust, or other foreign substances to stick to the
scanner. This may cause read errors.
Use a soft, dry cloth to wipe any substance from the scanner. (Do not use
a cloth dipped in alcohol or other cleaning substance.)
NOTICE
Long distance lens
1-2
Part Names and Functions
This section describes the part names and functions of the SR-750 Series.
NFPA79 compliant Ethernet cable
• OP-87359 (2 m cable)
• OP-87360 (5 m cable)
• OP-87361 (10 m cable)
Ethernet assembly plug
• OP-87362
400 mm lens
• SR-75L4
600 mm lens
• SR-75L6
Number
Name
Function
(1)
Scanner
Reads 2D codes and bar codes.
(2)
Power supply and
control port
Connect the control cable.
(3)
Ethernet port
Connect the Ethernet cable.
(4)
TEST button
Use this button to perform the following operations:
• Run 1 reading operation.
• Start and stop test mode.
• Run the multi-reading mode.
• Fix the communication settings of RS-232C to the default
values.
• Reset PLC link error.
(5)
TUNE button
Use this button to perform the following operations:
• Turn on the laser pointer for reading position adjustment.
• Start parameter tuning.
• Display the number of parameter banks of which the
alternate function is effective.
• Read the quick setup code.
• Reset errors.
• Start Ethernet communication BootP mode connection.
(6)
POW LED
When the power is turned ON, the "green" light turns on.
(7)
OK/NG/ERR LED
• When OK output is ON, the "green" light turns on.
• When NG output is ON, the "orange" light turns on.
• When ERR output is ON, the "red" light turns on.
(8)
NET LED
• When connected to Ethernet, the "green" light turns on.
• When the Ethernet data is sent/received, the "green" light
turns on.
(9)
IN LED
When an input terminal is on, this lights up.
(10)
Multiple LED
indicator
This displays the operation status including the bank
number upon successful reading, reading stability and
operation mode.
TEST
TUNE
POW ERR
NET IN
STB
OK/NG/
(4) TEST button
(5) TUNE button
(6) POW LED
(7) OK/NG/ERR LED
(8) NET LED
(9) IN LED
(10) Multiple LED indicator
(1) Scanner
(2) Power supply and
control port
(3) Ethernet port
300GB