• Input Only

This connection can perform the following communications.

• SR-750

→ PLC.............. Data Send

This connection is used only when sending read data of SR-750.
Multiple "Input only" connections can be used for a single unit of SR-750. (Max.
16)
For multiple PLCs to receive data transmission from a single SR-750, set the
PLCs as follows.

* Each connection's trigger timing is performed through cyclic. The SR-750

Series connection type supports both Point to Point and Multicast.

* When using the KV series, the connection names are assigned as follows.

1: Exclusive Owner

⇒result data / control data Class1

2: Input-Only

⇒result data Class1(Input-Only)

KV-5500 Series settings

Information regarding connection for KV-5500 and SR-D100 has been prepared.
Download the information from KEYENCE homepage.

Control/Compact Logix Series settings

The following is the procedure for registering the SR-750 Series in EtherNet/IP
communication using Control Logix.
Compact Logix can also be set using the same operation.

1

Right-click the EtherNet/IP enabled device on the RSLogix5000 and
select New Module.

2

Click the Communications' [+] button, select ETHERNET-MODULE
(Generic Ethernet Module), and click OK.

3

Set the ETHERNET-MODULE as follows:

CJ Series settings

1

Set the PLC network communication.

Using the CX-Developper, make the communication settings of PLC's IP
address, etc.

2

Set the EtherNet/IP network configuration for PLC and SR-750.

Using Network Configurator, set the network configuration.
* The EDS file for SR-750 is in the EDS folder on disc1 of SR-H3W.

3

Register the transmission area tag and the reception area tag for
PLC.

Right-click the PLC icon on Network Configurator, select [Parameter] – [Edit],
enter the [Edit device parameter] setting screen, and edit the tag.

4

Make the setting to relate the PLC tag with the SR-750 tag.

Register the device on the [Edit device parameter] setting screen and make the
connection assignment setting.
Transfer the configuration parameters to the PLC to complete the setting.

[Setting example]
Connection I/O type: Class1

* For operation details of CX-Developper and Network Configurator, see

"SYSMAC CS/CJ Series EtherNet/IP Unit User's Manual" published by Omron.

(1) Name

: Optional setting

(2) Comm Format

: Optional setting

*1

(3) IP Address

: SR-750 Series IP address setting

(4) Input (Assembly Instance)

: 100 (fixed)… Input the instance ID of result

data (Input Assemblies) in
decimal number.

(5) Input (Size)

: SR-750 Series Input assembly size setting

*4

(6) Output (Assembly Instance)

: 101 (fixed)… Input the instance ID of control

data (Output Assemblies) in
decimal number.

(7) Output (Size)

: SR-750 Series Output assembly size setting

*2*4

(8) Configuration

: 1

*3

(9) Configuration Size

: 0

*3

*1 This can be optionally set. However, considering the structure of the assembly

object, it is much easier to program if it set to a format in which 4-byte alignment is
possible.

*2 When operating using Input Only, set (6) to 254 and (7) to 0.
*3 The SR-750 Series does not use Configuration. However, input the above value

since not doing so will result in an incomplete input error.

*4 Input assembly size for the SR-750 Series is set in 8 bits (1-byte unit), the size for

RSLogix5000 is set in 32 bits (4-byte unit).
When setting, make sure that the SR-750 Input assembly size and Output
assembly size are the same or more of the values for (5) and (7).

Originator device (PLC)

Target device (SR-750)

Input tag set

E0_00000 - [500byte]

Output tag set

Input_100 - [500byte]

Connection type

Multi-cast connection

Output tag set

D00000 - [500byte]

Input tag set

Output_101 - [500byte]

Connection type

Point to Point connection

(1)

(2)

(3)

(4)

(6)

(8)

(5)

(7)

(9)