Data port 2 settings – KEYENCE SR-750 Series User Manual

Page 82

background image

82

E SR-750 UM

„

Data port 2 settings

Function

Command

Number

Setting

value

Explanation

Default

Remote IP address
(TCP communication)

300

a.b.c.d

a : 0 to 255
b : 0 to 255

c : 0 to 255

d : 0 to 255

Use when the protocol is TCP.

0.0.0.0

(Not set)

Remote port
(TCP communication)

301

1024 to
65535

Use only for TPC protocol.

5000

Protocol setting

303

0 to 5

0 : MC protocol
1 : SYSWAY

*1

2 : KV STUDIO
3 : None

or TCP

*2

4 : EtherNet/IP
5 : PROFINET

0

DM front address

304

MC:
0 to 32767
SYSWAY:
0 to 9999
KV:
0 to 65534

0

Control region address

305

MC:
0 to 7F
SYSWAY:
0 to 6143
KV:
1 to 599

0

Response region
address

306

MC:
0 to 7F
SYSWAY:
0 to 6143
KV:
1 to 599

0

Output data length
setting

307

001 to
100

* Set the upper limit of writing
length.

64

PLC link timing input

308

0, 1

0 : Disable
1 : Enable

0

Timing/Data wait

309

00 to 99 by the 100 ms

1

Retry duration (s)

310

01 to 30 by the second

5

EtherNet/IP
data handshake setting

321

0, 1

0 : Do not handshake
1 : Handshake

0

EtherNet/IP
Input assembly data
size setting

322

0040 to
1400

by 1

500

EtherNet/IP
Output assembly data
size setting

323

0040 to
1400

by 1

500

EtherNet/IP
Byte swapping setting

324

0, 1

0 : Disable (ROCKWELL)
1 : Enable (KEYENCE/OMRON)

0

PROFINET device
name

330

nnn…

Up to 240 characters
Specify with ASCII codes
* Device naming rule

1 : PROFINET device name

length: 1 to 240 characters

2 : 1 label length: 1 to 63

characters

3 : Only [a to z] (alphabet lower

case), [0 to 9] (numbers), [-]
(hyphen), [.] (period) can be
used for a device name.

4 : [-] (hyphen) cannot be used at

the beginning of the label.

5 : [-] (hyphen) cannot be used at

the end of the label.

6 : port-xyz, port-xyz-abcde

cannot be the name of the
first label.
abcde and xyz mean [0 to 9]
(numbers).

7 : Device names cannot be

made in the IP address
format.
(n.n.n.n n=0.….999)

8 : Labels cannot start with xn-.
9 : The first character of labels

cannot be a number.

If these rules are not observed, an
error occurs.

sr-750

PROFINET handshake

331

0, 1

0 : Do not handshake
1 : Handshake

0

*1: When Data port 2

is set to Ethernet,

1 cannot be used.

*2: Depends on the

Data port 2

configuration.

„

FTP Communication Settings

„

Master/Slave function settings

Function

Command

Number

Setting

value

Explanation

Default

IP address of the
connection destination
FTP server

400

a.b.c.d

a : 0 to 255
b : 0 to 255

c : 0 to 255

d : 0 to 255

For 0.0.0.0., the FTP client does
not operate.

0.0.0.0

(Not set)

User name of the
connection destination
FTP server

401

aaaa···

ASCII setting (max. 16 characters)

admin

Password of the
connection destination
FTP server

402

aaaa···

ASCII setting (max. 16 characters)

admin

Directory transfer at
connection

403

0, 1

0 : Disable
1 : Enable

0

Directly name of the
transfer destination

404

aaaa···

ASCII setting (max. 32 characters)

image

FTP connection request
transmission as
necessary

405

0, 1

0 : Disable
1 : Enable

0

NOOP command
transmission

406

0, 1

0 : Disable
1 : Enable

1

NOOP command
transmission interval

407

01 to 10 units: minute

1

PASV command
transmission

408

0, 1

0 : Disable
1 : Enable

0

Format setting for FTP
transmission

411

0, 1

0 : Bitmap
1 : JPEG

1

JPEG quality for FTP
transmission

412

01 to 10

05

Binning setting for FTP
transmission

413

0 to 3

0 : No binning
1 : 1/4 skipping
2 : 1/16 skipping
3 : 1/64 skipping

1

Function

Command

Number

Setting

value

Explanation

Default

Master/Slave operation
configuration

500

0 to 2

0 : Disable
1 : Multi drop link
2 : Multi head

0

Master/Slave ID during
operation

501

0 to 31

If 0 is set, it operates as Master.

0

Number of read data in
Multi Head mode

502

1 to 8

1

Master/Slave function
group name

503

nnnn…

Up to 16 characters
Specify with ASCII codes
* 0x20 to 0x7E of ASCII codes can

be used.

GROUP01