Available functions from the main screen, 2 operations on the main screens, Ig-e – KEYENCE IG Series User Manual
Page 43: Bas ic oper a tion s

3-2 Operations on the Main Screens
3-7
IG-E
3
B
as
ic Oper
a
tion
s
Available Functions from the Main Screen
Main screen
Press [MODE] button for approx. 2 seconds.
4-2 Basic Settings and Advanced Settings (page 4-4)
Basic settings
Basic settings such as measurement mode, response time
are made.
Advanced settings
More advanced settings such as hold function, delay timer
enable the unit to be used in wider applications.
Press
W and X buttons for approx. 2 seconds.
4-3 Setting the Measurement Sensitivity (page 4-44)
The measurement sensitivity can be adjusted according to
the amount of laser light received.
Press [MODE] and
W buttons for approx. 2 seconds.
4-4 Calculation Function (page 4-47)
The internal measurement value (R.V.) of two sets of the
sensor amplifier can be calculated (addition or subtraction).
Press [MODE] and
X buttons for approx. 2 seconds.
4-5 Calibration Function (page 4-52)
When there is difference between the internal measurement
value (R.V.) and the actual dimension of the object, the value
can be corrected.
While pressing the [MODE] button, press the [SET] button 5
times.
3-5 Initial Reset (Initialize) (page 3-10)
All of the setting items except for the calibration setting and
standard waveform registration are initialized.
LASER
BANK
0
1
2
3
HI
GO
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
HOLD
CALC
CHECK