Advanced settings tab (pro), Advanced settings tab (pro) -17 – KEYENCE IG Series User Manual
Page 139

6-4 Configuration Tab
6-17
IG-E
6
IG Config
u
ra
tion Softw
a
re (
IG-
H1)
Advanced settings tab (Pro)
Reference
For details on each function, refer to the sections below.
"4-2 Basic Settings and Advanced Settings" (page 4-4)
Item
Description
Hold Function
Setting range : Sample hold/Peak hold/Bottom hold/
Peak-to-peak hold/Auto peak hold/
Auto bottom hold
Default value : Sample hold
Trigger level
When the Auto peak hold or Auto bottom hold is set, the trigger level
can be set.
Setting range : -99.999 to 99.999
Default value : 0.100
Timing Input
When settings other than the Auto peak hold or Auto bottom hold
are set, the timing input can be set.
Default value : Level
Delay Timer
Setting range : OFF (not used)/ON-delay/OFF-delay/1-shot
Default value : OFF
Timer value
When values other than OFF are set, the delay time can be set.
Setting range : 1 to 9999
Default value : 60
Hysteresis
Setting range : 0.000 to 99.999
Default value : 0.020
Edge check function
Default value: OFF
Number of edges
When values other than OFF are set, the number of edges can be
set.
Setting range : 0 to 99
Default value
:
1
Main panel switching tab