Setting method (only main unit), 4 calculation function, Reference – KEYENCE IG Series User Manual
Page 109: Ig-e, Main screen

4-4 Calculation Function
4-51
IG-E
4
Setting V
a
ri
o
us
F
u
nct
ion
s
When the calculation function is used, the calculation process is added. Therefore, the
response time is delayed.
According to the number of additionally installed expansion units, add the following time to
the average number of times (response time) set on the main unit.
"3. Average number of times (Response time)" (page 4-17)
*1
"14. Interference prevention function (only for IG-1000/1500)" (page 4-40)
Setting Method (Only Main Unit)
Main screen
1
Press [MODE] button and
W button for approx. 2
seconds on the main screen at the same time.
[
.ECN] is displayed on the main display (upper level).
[MODE] +
W button
2 seconds or more
at the same time
2
Press
S / T button to set the mode and press [MODE]
or
X button.
If there is no expansion unit additionally installed, the setting
cannot be changed from [
QHH].
[MODE] or
X button
Main screen
3
When settings other than "The calculation function is
not used" are set on the main screen, the calculation
indicator "CALC" lights up.
LASER
BANK
0
1
2
3
HI
GO
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
HOLD
CALC
CHECK
Q((
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
%#.
GO
HOLD
CALC
CHECK
Mode
Setting
value
Description
Default
value
QHH
The calculation function is not used.
c
RNWU
Addition Mode
OKPWU
Subtraction Mode
JGCF
2 Heads Mode
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
HOLD
CALC
CHECK
GO
[CALC] ON
Response Time When the Calculation Function is Used
Number of installed units
(including the main unit)
Interference prevention
function
*1
OFF
Interference prevention
function ON
2
5 ms
7 ms
3
7 ms
7 ms
4
10 ms
14 ms
Reference
• When the calculation function is used, the setting of the average number of times
(Response time) for the expansion unit is the same as the one for the main unit.
• If connecting RS-232C Communication Unit DL-RS1A or the BCD Output Unit
DL-RB1A, add "7 ms" to the value in the table above.