Operation When the Power is Turned on for the First Time
When the amplifier is turned on for the first time after the sensor head is connected, the
initial setting screen appears after a few seconds. Make the initial settings according to the
following procedure.
The initial setting is necessary for both the main unit and the expansion units when units
are added.
4
Perform "3-3 Optical Axis Alignment" (page 3-8) and "3-4 Registering the
Standard Waveform (Gain adjustment)" (page 3-9).
Make other settings as necessary.
Note
The initial setting screen appears only when the power is turned on for
the first time. It will not appear when the power is turned on again. To
change these settings, perform the initial reset.
"3-5 Initial Reset (Initialize)" (page 3-10)
1
Press
S / T button to select the polarity of judgment
output and edge check output, and then press [MODE]
button.
[MODE] button
2
Press
S / T button to select the type of analog output
and press [MODE] button.
"10. Analog output scaling" (page 4-32)
[MODE] button
3
After the setting is complete, [
GPF] blinks several
times on the sub display and the main screen
appears.
Power ON
PRP
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
QWV
GO
HOLD
CALC
CHECK
Output polarity
Setting value
Description
PRP
NPN output
RPR
PNP output
QHH
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
#P.)
GO
HOLD
CALC
CHECK
Analog output
Setting value
Description
QHH
Not output
W
Analog output after the judgment value (P.V.) is converted
to the range from 0 to 5 V.
W
Analog output after the judgment value (P.V.) is converted
to the range from -5 to 5 V.
W
Analog output after the judgment value (P.V.) is converted
to the range from 1 to 5 V.
CORT
Analog output after the judgment value (P.V.) is converted to
the range from 4 to 20 mA.
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
GO
HOLD
CALC
CHECK
'PF