DISPLAY READS X Enter ~ Load ~ 0.00

6. Place a 100lb test weight on scale.

DISPLAY READS X Enter ~ Load ~ 99.66

7. Enter

.

DISPLAY READS X 100

8. Press

1

to establish span.

DISPLAY READS X 100.00

9. Pause for motion delay.

DISPLAY READS X Cal ~ Good? ~ 100.00

10. Press

1

to accept calibration.

DISPLAY READS X Enter ~ =Stor

11. Press

1

to save calibration.

DISPLAY READS X Enter ~ =End

12. Press

1

to exit calibration.

DISPLAY READS X 100.00

13. Remove the calibration weight.

DISPLAY READS X 0.00

First Zero Calibration Method Example (355):

1. From the Weigh Mode key in

!

.

DISPLAY READS X Setup

2. Key

in

(

.

DISPLAY READS X Fast ~ Cal~First ~ Zero? ~ -0.26

3. Remove any load on the scale.

DISPLAY READS X First ~ Zero? ~ -0.42

4. Press

(

to establish zero.

DISPLAY READS X 0.00

5. Pause for motion delay.

DISPLAY READS X Enter ~ Load ~ 0.00

6. Place a 100lb test weight on scale.

DISPLAY READS X Enter ~ Load ~ 99.66

7. Enter

.

DISPLAY READS X 100

8. Press

(

to establish span.