beautypg.com

Holtgreven GSE-355 I.S. User Manual

Page 61

background image

52

Determines the TIME format style, 12 hour or 24 hour. If in 12 hour mode the right most decimal
point on the LED display will become the PM indicator. Note: The time must be entered as military
time. If the mode is set for 12 hour, the time will be converted to a 12 hour clock.

P504

Style (toggle)

Determines the DATE format style, U.S.A. or Int’l. If set for U.S.A, the date will resemble 01/26/01.
If set for international, the date will resemble 26/01/01.

P505 Time/Date

Select (toggle)

Allows the time and date to be viewed with the

!

key from the weigh mode. The weight will continue to be

updated when viewing the time or date. The time will be formatted as defined by P503 and the date will be
formatted as defined by P504

P800

Remote Key Operation (Selection)
Select function for Remote Key closure. Choose from None, Print, Tare or Zero. If a setpoint is configured to
use the remote key as an activation method, then the P800 setting is over-ridden. The Remote Key Operation
section on page 83 details the remote key operation. See Remote Key Connection on page 12 for remote key
electrical connections.

P1000 Custom

Transmit

of the custom transmit table and must be enabled for transmit by selecting choice 0 at P213. Parameters use
three bytes of memory; ASCII characters and control codes use one byte. See P60001 for available memory.
The custom transmit cannot be viewed or altered from the indicator. A custom transmit must be entered via the
serial port. See Custom Transmit Setup on page55 for details on designing and loading a custom transmit.

P5000 355 Target Key (Toggle)

Allows a target value to be entered or viewed. This parameter will only appear when a 355 keypad is detected.
Sending a %g using a serial device such as a computer is equivalent to pressing the Target key.

P5002 355 Stop Key (Toggle)

Enable or disable the use of the stop key from the 355 keypad. This parameter will only appear when a 355
keypad is detected. Sending a %h using a serial device such as a computer is equivalent to pressing the Stop
key.

P5003 355 Start Key (Toggle)

Enable or disable the use of the start key from the 355 keypad. Pressing the Start key in the weigh mode with
setpoints enabled causes a paused setpoint operation to be resumed. In setpoint modes other than
checkweighing, the Start key performs the same operation as a remote key. This parameter will only appear
when a 355 keypad is detected. Sending a %y using a serial device such as a computer is equivalent to
pressing the Start key.

P5004 355 Restart Checkweighing Mode (Toggle)

Determines the method in which the checkweighing mode will be restarted. Auto will restart after return to

zero or Manual will restart by pressing the

&

key.

P5010 Setpoint Annunciators (Toggle)

Enables or disables the setpoint annunciators to the left of the main 7-segment display. Disabling the setpoint
annunciators may be desired when the bargraph is enabled while using an LCD display. See Bargraph
(General)
on page 66.

P5011 Setpoint Bargraph (Toggle)