Holtgreven GSE-355 I.S. User Manual
Page 74

65
C
HANGING
T
ARGETS FROM THE
W
EIGH
M
ODE
(G
ENERAL
)
When a setpoint operation is configured from the Setup Mode, certain parameters are made available in the Weigh
Mode. Pressing
!
cycles through available modes (Gross, Net, Quantity, Targ 1, etc.).
When viewing a setpoint-related parameter from the Weigh Mode,
#
takes on a special function. Data keyed in
prior to
#
will be displayed as the new setpoint parameter value. Pressing
#
alone will advance to the first subset
for the current setpoint parameter. Pre-acts and tolerances are subsets of their respective target values.
A negative target value many be entered for the independent setpoints only. To enter the negative sign press
then
+
2
(Model 350 IS) or
#
(Model 355 IS). A negative sign will be displayed. Press
#
to continue with
the entry
Programs that involve a discharge cycle are loss-in-weight type applications. Any target or pre-act values for these
programs should be entered as positive numbers. The 350/355 will automatically interpret these values as negative.
E
XAMPLE
(G
ENERAL
)
The target for the fill setpoint operation is Targ 1. This is a setpoint-related parameter and automatically becomes an
available mode when Fill is configured in the setpoint setup. Pre-act 1 and pre-act 2 are subsets of Targ 1. The
following procedure illustrates how to change a target from 250 lbs to 400 lbs., keep pre-act 1 at 28 lbs. and change
pre-act 2 from 1.5 lbs to .5 lbs.
To change targets from the Weigh Mode (350 IS):
1. Press
.
DISPLAY READS X0.00
2. Press
to view the current fill target.
DISPLAY READS XTarg1 ~ 250
3. Press
1
to set a new fill target of 400 lbs.
DISPLAY READS XTarg1 ~ 400
4. Press
1
to select the Pre-Act 1 (subset) value of 28 lbs.
DISPLAY READS XPA 1 ~ 28
5. Press
1
to select the Pre-Act 2 (subset) value of 1.5 lbs.
DISPLAY READS XPA 2 ~ 1.5
6. Press
1
to select a new Pre-Act 2 value of .5 lbs.
DISPLAY READS XPA 2 ~ .5
7. Press
to display the current Gross Weight.
DISPLAY READS X15.12