Holtgreven GSE-355 I.S. User Manual
Page 11
2
Input (J4): 12 – 26VAC / 12 – 36 VDC
One of four wall mount transformers supplied:
North American:
Input: 120VAC, 30W, 60 Hz
Output: 20VAC, 800mA
United Kingdom / Ireland:
Input: 230VAC, 28W, 50 Hz
Output: 20VAC, 800mA
Continental Europe:
Input: 230VAC, 28W, 50 Hz
Output: 20VAC, 800mA
IEC 320: (table top transformer with IEC 320 receptacle)
Input: 230VAC, 28W, 50 Hz
Output: 20VAC, 800mA
350/355 Stainless Steel Enclosure
Input (J10): 85 – 265VAC, 0.5A; 50/60 Hz (internal power supply version)
Input (J3): 10 – 36VDC, minimum 0.8A w/no options or 1.25A w/options installed (internal power supply version)
Excitation Voltage
10 VDC
Excitation Current
180 mA max. / (6) 350
Ω bridge
F.S. Signal Input
0.1 mV/V min – 20 mV/V max
Signal Connection
4 lead or 6 lead with sense
PROCESS CONTROL
Outputs
See
OPTIONS
Remote Input
1 momentary contact closure (100ms minimum)
TARE,
PRINT,
ZERO
COMMUNICATIONS
Serial
RS232
bi-directional
serial
port
Data Output
14 selectable fixed-format transmissions or
1 custom format (programmable via RS232)
Protocol
Selectable
Baud Rate
150 – 9600 bps
DISPLAY
LED
6-digit weight display, 0.8” (22mm) height
11
LED
annunciators
for
operational
status
LCD
6-digit weight display, 1.0” (25.4mm) height
11 LCD annunciators for operational status
Built in LCD status bargraph
ENCLOSURE
Zinc Die Cast
Black powder coat paint, self-standing on flat surface
Wall/Ceiling Mount
Optional stainless steel swivel bracket
Shipping
Weight
7
lb
(3
kg)
Stainless
Washdown stainless steel enclosure w/stainless steel swivel bracket (table, wall or
ceiling mount)
OPTIONS
Analog Output Module
0–10 VDC/5mA, 0–20mA/10V, 4–20mA/10V, electrically isolated, 16 bit
resolution with up to 10 updates per second response time, mounts internal to
enclosure
Relay Output Module
Three (3) solid-state 24–280 VAC, 1A with up to 10 updates per second response
ime, mounts internal to enclosure or three (3) 3– 60 VDC, 2A