beautypg.com

Holtgreven GSE-355 I.S. User Manual

Page 76

background image

67

NOTE: Right-side bars will have the same scaling (lb per bar) as the left-side bars. They are represented as a mirror
image of each other.

Bars ON Weight Range (Lower Tolerance Limit)

9

<

10

8 10.00 to 15.00
7 15.00 to 20.00
6 20.00 to 25.00
5 25.00 to 30.00
4 30.00 to 35.00
3 35.00 to 40.00
2 40.00 to 45.00
1

45.00 to 50.00

Figure 31: Example #2 Bargraph Segments (Weighted Value)

Figure 32: Examples of the Bargraph "Below, Within and Above Tolerance"


NOTE: (bargraph for filling and emptying modes)

For modes other than check-weighing, the bars will be on only while the setpoints are on and during the "Done" at the
end of a fill.

The bar weights will be calculated similar to the check-weigh modes of operation stated above for filling, batching,
etc., except that the percentage will be based on the actual target, rather than the low-limit value (see the equation
below). The operation for emptying (and the emptying portion of 'both') will be the same except that the weight will be
going negative while the left side bars are turning off.