Custom Transmit

The serial output of the Model 350/355 can be configured for a custom application such as a remote display format, a
customized computer program format, or a customized ticket format. The custom transmit must be designed in a
computer-transmittable ASCII text file. The custom transmit can only be loaded into the indicator through the serial
port. P213 must be set to 0 to select the custom transmit format for transmission.

E

LEMENTS OF A

C

USTOM

T

RANSMIT

Parameters, ASCII text, and control codes are the elements of a custom transmit.

Parameters

Certain parameters related to weight, quantity, setpoints and status can be sent out of the comm port. Gross Weight,
Target 1 and Quantity are examples of printable parameters.

ASCII Text

ASCII text can be entered into a custom transmit to provide further detail of a transaction. “P”, “@” and “+” are
examples of ASCII text.

Control Codes

You can custom transmit ASCII control codes to control a printing device. (carriage return) and (form
feed) are examples of control codes.

W

RITING A CUSTOM TRANSMIT

ASCII

TEXT FILE

Any text editor may be used to construct a custom transmit (Notepad, Wordpad, etc.), but you must save the custom
transmit as a text (.txt) file. Instructions can also be sent keystroke by keystroke from a communications program. To
do so, ignore the Model 350/355 display and enter the characters in the correct order. Figure 29 shows a custom
transmit written in Wordpad.

A

CCESSING

S

ETUP AND

C

LEARING

E

XISTING

C

USTOM

T

RANSMIT

Every custom transmit file must start with:

1999%s%s%z%p%u%e
%c%e


This accesses the Setup Mode at the end of the existing transmit and then clears the transmit so that a new one may be
entered.