Pre-acts 1 and 2 are always available as subsets of their respective targets from the Weigh Mode.


Since the discharge portion of the Both cycle is a loss-in-weight operation, target 2 and pre-act 2 entries are entered as
positive values and interpreted by the indicator as negative. See Changing Targets from the Weigh Mode (General) on
page 65 for detailed instructions on changing target values from the Weigh Mode.

E

XAMPLE

(B

OTH

)

With a system set up to fill a weigh vessel with 2000 lbs. of paint and to meter out the paint in 45 lb buckets, the
following settings might be used:

Parameter Setting

Actual Cutoff Value

Comments

Targ 1 = 2000

Desired vessel fill target.

Based = Net

Targets are compared to net weight.

PA 1 = 5

2000 – 5 = 1995

Fill valve closes at 1995 lbs.

Learn 1 = Enabled

Analyze five previous fills and auto-adjust pre-act 1.

Start 1 = R-but

Start fill with remote key closure.

Targ 2 = 45

0 – 45 = (-45)

Desired discharge target (decreasing weight from a net
zero: enter as a positive value).

PA 2 = 5

45 – 5 = 40

0 – 40 = (-40)

Discharge valve closes at
(-40) lbs. (decreasing weight from a net zero: enter as a
positive value).

Learn 2 = Enabled

Analyze five previous discharges and auto-adjust pre-act 2.

Start 2 =

#

Start discharge with

#

.

Pause = None

Disable pause function.

Independent Setpoint Operation

Independent Setpoints allow controlling setpoints when the gross, net or quantity (if counting is enabled) is above or
below a target value. The reset (deactivation) choice of each setpoint is selectable from Tare, Remote Key, Auto, Non-
latching
or Absolute. See Key-In Parameters on page 43 for instructions on using front panel keys for data entry.

Table 22: Setpoint Setup (Independent)

Setpoint

Selection

Function

Description

P5100.7 Indep

Independent

Setpoints.

P5121.1

Base 1

Select from Net, Gross or Count (Quantity) for setpoint 1.

P5122.0 Act

1

Activate setpoint 1 when weight is above or below.

P5123.--

Targ 1

Setpoint 1 target for weight to either rise above or fall below.

P5124.0

Stbl 1

Setpoint 1 activation stability setting.

P5125.0

Rset 1

Reset selection for setpoint 1.

P5126.--

Rtrg 1

Value for reset. *Only available if “Value” is selected for Reset 1.

P5127.1

Rstb 1

Reset 1 stability setting.

P5131.1

Base 2

Select from Net, Gross or Count (Quantity) for Setpoint 2.

P5132.0

Act 2

Activate setpoint 2 when weight is above or below.

P5133.--

Targ 2

Setpoint 2 target for weight to either rise above or fall below.

P5134.0 Stbl

2

Setpoint

2 stability setting.

P5135.0

Rset 2

Reset selection for setpoint 2.

P5136.--

Rtrg 2

Value for reset. *Only available if “Value” is selected for Reset 2.