Independent setpoint operation, Xample – Holtgreven GSE-355 I.S. User Manual
Page 84
![background image](/manuals/657678/84/background.png)
75
Pre-acts 1 and 2 are always available as subsets of their respective targets from the Weigh Mode.
Since the discharge portion of the Both cycle is a loss-in-weight operation, target 2 and pre-act 2 entries are entered as
positive values and interpreted by the indicator as negative. See Changing Targets from the Weigh Mode (General) on
page 65 for detailed instructions on changing target values from the Weigh Mode.
E
XAMPLE
(B
OTH
)
With a system set up to fill a weigh vessel with 2000 lbs. of paint and to meter out the paint in 45 lb buckets, the
following settings might be used:
Parameter Setting
Actual Cutoff Value
Comments
Targ 1 = 2000
Desired vessel fill target.
Based = Net
Targets are compared to net weight.
PA 1 = 5
2000 – 5 = 1995
Fill valve closes at 1995 lbs.
Learn 1 = Enabled
Analyze five previous fills and auto-adjust pre-act 1.
Start 1 = R-but
Start fill with remote key closure.
Targ 2 = 45
0 – 45 = (-45)
Desired discharge target (decreasing weight from a net
zero: enter as a positive value).
PA 2 = 5
45 – 5 = 40
0 – 40 = (-40)
Discharge valve closes at
(-40) lbs. (decreasing weight from a net zero: enter as a
positive value).
Learn 2 = Enabled
Analyze five previous discharges and auto-adjust pre-act 2.
Start 2 =
#
Start discharge with
#
.
Pause = None
Disable pause function.
Independent Setpoint Operation
Independent Setpoints allow controlling setpoints when the gross, net or quantity (if counting is enabled) is above or
below a target value. The reset (deactivation) choice of each setpoint is selectable from Tare, Remote Key, Auto, Non-
latching or Absolute. See Key-In Parameters on page 43 for instructions on using front panel keys for data entry.
Table 22: Setpoint Setup (Independent)
Setpoint
Selection
Function
Description
P5100.7 Indep
Independent
Setpoints.
P5121.1
Base 1
Select from Net, Gross or Count (Quantity) for setpoint 1.
P5122.0 Act
1
Activate setpoint 1 when weight is above or below.
P5123.--
Targ 1
Setpoint 1 target for weight to either rise above or fall below.
P5124.0
Stbl 1
Setpoint 1 activation stability setting.
P5125.0
Rset 1
Reset selection for setpoint 1.
P5126.--
Rtrg 1
Value for reset. *Only available if “Value” is selected for Reset 1.
P5127.1
Rstb 1
Reset 1 stability setting.
P5131.1
Base 2
Select from Net, Gross or Count (Quantity) for Setpoint 2.
P5132.0
Act 2
Activate setpoint 2 when weight is above or below.
P5133.--
Targ 2
Setpoint 2 target for weight to either rise above or fall below.
P5134.0 Stbl
2
Setpoint
2 stability setting.
P5135.0
Rset 2
Reset selection for setpoint 2.
P5136.--
Rtrg 2
Value for reset. *Only available if “Value” is selected for Reset 2.