beautypg.com

Holtgreven GSE-355 I.S. User Manual

Page 60

background image

51

Enable / disable the RS-485 multi-drop network option. Requires that an RS-485 option board be installed.
This option allows up to 250 RS-485 devices to be networked together in either a half duplex or full duplex
wiring scheme. See the RS-485 Multi-Drop Network Setup and Operation section beginning on page 86 for
complete details on RS-485 setup and operation.

P251

Address (Key in)
Specifies the address of the controller for RS-485 multi-drop communications. Allowed choices are 0
(disabled) and 4 – 254.

P410 Euro

(Toggle)

Enable OIML legal-for-trade restrictions (see Chapter 6: Legal For Trade).

P420 Display

(Selection)

Select display control option. Choose from On, Off or Auto. The auto setting helps conserve power for
extended battery life. When the indicator display is off, the load cell(s) are still powered.

If P420 is set to Off or selection 0, you can turn on the display by holding down the

"

key upon power up.

This does not set P420 to On; it only temporarily turns on the large VFD display in order to allow you to see
what you are entering.

Parameter

Setting

Choice Description

P420.00

Off

Shuts off the display.

P420.01

On

Normal display operation.

P420.02

Auto

Shuts off the display when weight has stabilized within
6 divisions for 5 minutes. Pressing [ON] or changing
weight more than 6 divisions will re-enable the display.
NOTE: The display will turn back on if data is received
via the RS-232 Port.

P423

Back Light (on/off)
Toggle the backlight on a 350/355 LCD

P426

Low Battery Indication (Toggle)

Press

#

to enable or disable this option. Low battery will be indicated continuously if this feature is

enabled without the battery option installed. Otherwise, an annnunciator will be lit when the battery voltage is
low.

P427

Battery Option Automatic Shutdown (Selection)

Select duration of time for auto shutdown. Choose from selections with the

#

key. Selections are off, 0.5,

1, 2, 3, 4, 5, 10, 15, 20, 25, 30, 35, 40, 45, and 60. Choices are in set in minutes.

P440

Legal For Trade Restrictions (Toggle)
Enable NTEP legal-for-trade restrictions. See Chapter 6: Legal For Trade.

P502 Time/Date

(toggle)

Enables or disables the time and date feature. If enabled the indicator will prompt the user to enter the
correct date and time upon power up. Note: if disabled P503-P505 will not be accessible, however,
their current settings will be retained for future use.

P503 Hours

(toggle)