Arameter, Etails – Holtgreven GSE-355 I.S. User Manual
Page 57

48
Parameter
Number
Display
Name
Default
Value
Valid Range/ Choices
Parameter
Description
Page
P410.--
Euro
Disable
Enable / Disable
9991/9990 (Key In)
OIML Enforce
51
P420.01
Dsply
On
Off – Auto
(3 Selections)
Display Function
51
P423.00
Backlight
Off ON/OFF
(Toggle)
Backlight 51
P426.00
Batt
Disable
Enable / Disable
(Toggle)
Battery Option
annunciator
51
P427.00
Apo
Off
Off – Cycle
(15 Selections)
Auto Power for
Battery Option
51
P440.00
rStrc
Disable
Enable / Disable
(Toggle)
NTEP Enforce
51
P502.01
disbl
t-dAt
Disable
Enable / Disable
(Toggle)
Time/Date
Function
51
P503.01
12 hours
12 hour
12 hour/24 hour
Time/Date
Function
51
P504.00
Style
U.S.A
U.S.A or International
Time/Date
Function
52
P505.01
TdSEL
disbl
Disable
Enable / Disable
(Toggle)
Time/Date
Function
52
P800.00
R-But
None
None – Setpoint
(5 Selections)
Remote Button
Function
52
P1000.--
Cust. Trans
-- --
Custom
Transmit
51
P5010.00
SPAnn
Enable
Enable / Disable
(Toggle)
Setpoint
Annunciators
52
P5011.00
SPBar
Disable
Enable / Disable
(Toggle)
Bargraph Display
52
P5012.00
BarPc
50%
0 – 100
(Key In)
Bargraph Scaling
53
P5100.00
SetPt
None
None – Indep
(8 Selections)
Setpoint Operation
53
P
ARAMETER
M
AP
D
ETAILS
P110
Full Scale Value (Key in)
Denotes the full scale capacity. This value should not exceed the rated capacity of the weighing device.
P111
Division Size (Selection)
Indicates the count-by and decimal point. Pressing
+
1
(Model 350) or
(Model 355) will
automatically select the choice closest to 10,000 divisions without exceeding 10,000 divisions.
P112
Zero Track Aperture (Selection)
Set in terms of number of divisions. Zero tracking eliminates small weight deviations at or near zero. Weight
deviations within the selected window that have been stable for more than one second are tracked off,
maintaining a gross or net zero condition.
The sum of weight values zeroed with auto zero tracking and
"
cannot exceed the allowable zero range
(P118).
Truck scales commonly use zero tracking to compensate for snow fall. To determine the proper setting in a
counting application, divide the weight of the smallest product counted by the division size (P111). Zero Track
should be set to 0 (off) for most setpoint filling operations. This prevents tracking off any product trickle at the
start of a fill process.
P114 Stability
(Selection)