according to the percentages entered. The desired target may be based on gross weight, net weight or quantity (if
counting is enabled). Only the annunciators will light to indicator the setpoint status. Physical setpoints cannot be
added at this time. The setpoint modules will be available in the near future and will be installed in a safe area hub.
Table 23: Setpoint Setup (Percentage Check-Weighing)
Setpoint
Selection
Function
Description
P5100.1 ChecP
Check-weigh by percentage.
P5101.-- Targ1
Absolute
target
value.
P5102.--
PctLo
Low acceptance percentage.
P5103.--
PctHi
High acceptance percentage.
P5104.0 Based
Select
from
Net, Gross or Quantity.
See Key-In Parameters on page 43 for instructions on using the front panel keys for entering data.
S
ETPOINT
A
CTIVATION
(P
ERCENTAGE
C
HECK
-W
EIGHING
)
In order for the annunciators to activate, the displayed value must be at least five graduations above zero.
Check-Weigh
Status
Annunciator
Status
Annunciator
Color (LED)
OVER
SP 1
Illuminated
Red
GOOD
SP 2
Illuminated
Green
UNDER
SP 3
Illuminated
Yellow
The Pre-Acts, Learn Mode, and Pause Feature options are not applicable to check-weigh operation.
C
HANGING
T
ARGETS FROM THE
W
EIGH
M
ODE
(P
ERCENTAGE
C
HECK
-W
EIGHING
)
When Check-Weigh by Percentage is configured in the setpoint setup, the Targ 1 value automatically becomes an
available mode for the
!
key. Keying in a value before pressing
#
changes Targ 1. Targ 1 is entered as an
absolute value. Pressing
#
alone gives access to the subsets. PctLo and PctHi are the subsets for Targ 1. PctLo and
PctHi are entered as percentage values.
To change targets from the Weigh Mode:
1. Press
!
to view the current net weight.
DISPLAY READS X0.00
2. Press
!
to view the current fill target.
DISPLAY READS XTarg1 ~ 250