Setting up the redundant erdb, Setting up the redundant erdb -18 – Rockwell Automation 1757-SWKIT5100 ProcessLogix R510.0 Installation and Upgrade Guide User Manual
Page 178

Publication 1757-IN510A-EN-P - October 2003
6-18 Additional Redundant Server Procedures
Setting up the Redundant
ERDB
Complete the following steps on
SERVERB only:
1 . Open Station.
2. Click the Oper field in the lower right corner of the display
3. Enter >mngr< in the Station logon prompt and click OK.
4. Click Configur e
⇒ Operator ⇒ Operators.
5. Click the mngr Operator ID.
6. Click Change Passwor d.
7. Enter the New Password, Confirm the New Password and click
OK.
The message
Passwor d accepted should appear in the message
zone. If it does not repeat steps 6 and 7.
Only systems using operator based security and Control Builder
are affected by this change. The mngr operator account is
different than the Windows mngr user account. Navigate in
Knowledge Builder to Administration and Startup Guide for
more information before changing the password of the
Windows mngr user account.
8. Click Star t
⇒ Pr ograms ⇒ Pr ocessLogix Engineering Tools
⇒ DB Admin.
9. Click the
+
sign to expand DbAdmin.
1 0. In the Login dialog box, make these entries:
a. Enter >mngr< as the default User Name.
b. Enter the appropriate Password.
c. Enter
SERVERB in the Server Name field.
d. Select
Classic Ser ver Secur ity in the Domain Name
drop-down list.
1 1 . Click OK.
1 2. Click the
+
sign to expand the ProcessLogix Node.
1 3. Click Admin Tasks.
1 4. Click Disable Replication.