Rockwell Automation 1758-RTU202 DataSite Software User Manual FRN 1.2 User Manual
Page 273

Publication 1758-UM002D-EN-P - October 2010
Extension Modbus Protocol for DataSite Controllers (1758-FLO) 273
Modbus addresses for calculation results block 2
Meter Run
Starting Address
Parameter
Address
Address Number
0
33101
X
50
1
33151
X + 50
50
2
33201
X + 100
50
3
33251
X + 150
50
4
33301
X + 200
50
5
33351
X + 250
50
6
33401
X + 300
50
7
33451
X + 350
50
Parameters in calculation results block 2
Parameter Name
Description
Data Type
Modbus Addresses
for Meter Run 0
Parameters (= X)
qeh_pval
Energy hour flow rate
float
33101…33102
qe_yesterday
Energy flow of the previous day
float
33103…33104
avh_EXT
Hourly average of the square root of the product of static pressure and
differential pressure. This is also the average uncorrected volume
(AGA7) for the hour.
float
33105…33106
avd_EXT
Daily average of the square root of the product of static pressure and
differential pressure. This is also the average uncorrected volume
(AGA7) for the day.
float
33107…33108
avh_Gr
Average real relative density for the hour
float
33109…33110
avd_Gr
Average real relative density for the day
float
33111…33112
Y2
Expansion fsactor based on the absolute static pressure measured at
the downstream tap
float
33113…33114
Reserved
Reserved
float
33115…33150