Rockwell Automation 1758-RTU202 DataSite Software User Manual FRN 1.2 User Manual
Page 191
Publication 1758-UM002D-EN-P - October 2010
DataSite Flow Configuration Utility (DS FloConfig) 191
AGA8 Methods
Gas analysis
Calculation interval
1
BMP (Base Multiplier Period)
1
Base Pressure
14.73
Base Temperature
60
DP Cutoff
0
Pressure Type
Absolute
Atmospheric Pressure
14.73
Static Pressure Tap Location
Upstream
Orifice Material
304 and 316 stainless steel
Orifice Diameter
4
Orifice Measurement Reference Temperature
68
Tube Material
Carbon steel
Tube Diameter
8.071
Tube Measurement Reference Temperature
68
Relative Density Condition Type
Real
Relative Density
0.58122
Reference P for Relative Density
14.73
Reference T for Relative Density
60
Gas Heating Value
1035.99
Reference T for Gas Heating Value
60
Pressure Register
0
Pressure Data Type
Ushort
Pressure K Factor
0.0625
Pressure B Factor
-625
Temperature Register
0
Temperature Data Type
Ushort
Temperature K Factor
0.005
Temperature B Factor
-50
DP Register
0
DP Data Type
Ushort
DP K Factor
0.005
DP B Factor
-50
Pulse Register
0
Pulse Data Type
Ushort
Pulse K Factor
0.005
Default values of AGA flow parameters (Continued)
Parameter Name
Default Value