beautypg.com

Rockwell Automation 1758-RTU202 DataSite Software User Manual FRN 1.2 User Manual

Page 191

background image

Publication 1758-UM002D-EN-P - October 2010

DataSite Flow Configuration Utility (DS FloConfig) 191

AGA8 Methods

Gas analysis

Calculation interval

1

BMP (Base Multiplier Period)

1

Base Pressure

14.73

Base Temperature

60

DP Cutoff

0

Pressure Type

Absolute

Atmospheric Pressure

14.73

Static Pressure Tap Location

Upstream

Orifice Material

304 and 316 stainless steel

Orifice Diameter

4

Orifice Measurement Reference Temperature

68

Tube Material

Carbon steel

Tube Diameter

8.071

Tube Measurement Reference Temperature

68

Relative Density Condition Type

Real

Relative Density

0.58122

Reference P for Relative Density

14.73

Reference T for Relative Density

60

Gas Heating Value

1035.99

Reference T for Gas Heating Value

60

Pressure Register

0

Pressure Data Type

Ushort

Pressure K Factor

0.0625

Pressure B Factor

-625

Temperature Register

0

Temperature Data Type

Ushort

Temperature K Factor

0.005

Temperature B Factor

-50

DP Register

0

DP Data Type

Ushort

DP K Factor

0.005

DP B Factor

-50

Pulse Register

0

Pulse Data Type

Ushort

Pulse K Factor

0.005

Default values of AGA flow parameters (Continued)

Parameter Name

Default Value