Initialize the file system – Rockwell Automation 1758-RTU202 DataSite Software User Manual FRN 1.2 User Manual
Page 194
Publication 1758-UM002D-EN-P - October 2010
194 DataSite Flow Configuration Utility (DS FloConfig)
Initialize the File System
The File System Initialization option lets you do the following:
•
Clear all the parameter settings made in DS Settings, for example, Scan
block, HART scan block and PID block settings.
•
Clear DNP3 parameters
•
Clear registers
This is equivalent to selecting the following check boxes:
•
Register Initialization
•
DNP3 Initialization
•
DS Workbench initialization
Follow these steps to initialize the file system.
1.
Set the controller into the Service mode.
2.
Select the File System Initialization check box.
3.
Click Set.
The new settings are downloaded to the controller.
4.
Click Run, and exit the service mode.
TIP
When the File System Initialization check box is
selected, the AGA Parameter Initialization, AGA Files
Initialization, DS Workbench Initialization and DNP3
Initialization check boxes are cleared. This is because
the File System Initialization function includes these
other functions.