Technical data, Rated data – Lenze ECSCAxxx User Manual
Page 43
Technical data
Rated data
l
43
EDBCSXA064 EN 3.2
Rated data
Type
Axis module
ECSx
L032
ECSx
L048
ECSx
L064
Output power 400 V mains
S
rated
[kVA]
8.3
11.2
13.2
Data for operation with upstream power supply module
on mains voltage
U
mains
[V]
400
480
400
480
400
480
DC−bus voltage
V
DC−bus
[V]
15 ... 770
DC−bus current
I
DC−bus
[A]
15.6
12.5
20.9
16.8
24.5
19.6
Rated output current at 4 kHz
(causes a heatsink temperature of 70°C at an ambient
temperature of 20°C)
I
r
[A]
12.7
10.2
17.0
13.6
20.0
16.0
Rated output current at 8 kHz
(at an ambient
temperature of 20°C it causes a heatsink temperature
of 70°C)
1)
I
r
[A]
8.5
6.8
11.3
9.0
13.3
10.6
Max. output current
(acceleration current)
I
max
[A]
32.0
48.0
64.0
Continuous current at standstill
2)
(holding current at 90°C, 4 kHz)
I
0,eff 4 kHz
[A]
16.0
12.8
23.0
18.4
27.0
21.6
Short−time standstill current
(holding current at 90 °C, 4 kHz)
2)
I
0,eff 4 kHz
[A]
18.1
27.2
36.3
Short−time standstill current
(holding current at 70 °C, 4 kHz)
2)
I
0,eff 4 kHz
[A]
24.0
36.0
48.0
Short−time standstill current
(holding current at 70 °C, 8 kHz)
2)
I
0,eff 8 kHz
[A]
12.1
18.1
24.2
Power loss (operation with rated
current at 4 kHz / 8 kHz)
Total
P
loss
[W]
144.5
166.5
199.0
Inside the device
27.5
34.5
41.0
Heatsink
117.0
132.0
158.0
Max. output frequency
f
out
[Hz]
600
Mass
m [kg]
approx. 2.4
approx. 3.3
1)
If the heatsink temperature reaches 70°C, the switching frequency automatically changes to 4 kHz.
2)
The indicated temperature is the measured heatsink temperature (C0061).
L
Application software:
S = Speed & Torque
P = Posi & Shaft
M = Motion
A = Application