System modules – Lenze ECSCAxxx User Manual
Page 344
System modules
DIGITAL_IO (node number 1)
Inputs_DIGITAL (digital inputs)
l
344
EDBCSXA064 EN 3.2
Codes
Code
Possible settings
IMPORTANT
No.
Designation
Lenze/
{Appl.}
Selection
C0114
Polarity of the digital inputs
^ 129
1 DIGIN pol
0
HIGH level active
X6/DI1 (DIGIN_bIn1_b)
2 DIGIN pol
0
HIGH level active
X6/DI2 (DIGIN_bIn2_b)
3 DIGIN pol
0
HIGH level active
X6/DI3 (DIGIN_bIn3_b)
4 DIGIN pol
0
HIGH level active
X6/DI4 (DIGIN_bIn4_b)
0
HIGH level active
1
LOW level active
C0443 DIS: DIGIN
Signal status of the digital inputs
on X6 after consideration of the
polarity set under C0114.
Only display
^ 343
0
{1}
255
Bit 0
DIGIN1
X6/DI1
Bit 1
DIGIN2
X6/DI2
Bit 2
DIGIN3
X6/DI3
Bit 3
DIGIN4
X6/DI4
Bit 4
DIGIN_safe_standstill
X6/SI2
0: Pulse inhibit is active
1: Pulse inhibit is inactive
^ 80
Bit 5
Free
Bit 6
DIGIN_CInh
X6/SI1
0: Controller is inhibited (CINH)
1: Controller is enabled
^ 80
Bit 7
Free
Terminal assignment
Terminal
Function
X6
Digital inputs
X6/DI1
Digital input 1
(DigIn_bIn1_b)
freely assignable
X6/DI2
Digital input 2
(DigIn_bIn2_b)
X6/DI3
Digital input 3
(DigIn_bIn3_b)
X6/DI4
Digital input 4
(DigIn_bIn4_b)
X6
Connection of "Safe torque off"(
^ 80)
X6/SI1
Input 1
LOW
DIGIN_bCInh_b = TRUE
HIGH
DIGIN_bCInh_b = FALSE
X6/SI2
Input 2
LOW
DIGIN_b_safe_standstill_b = FALSE
HIGH
DIGIN_b_safe_standstill_b = TRUE
X6/S24
Low−voltage supply