System bus (can / can−aux) configuration – Lenze ECSCAxxx User Manual
Page 164
System bus (CAN / CAN−AUX) configuration
Setting the boot−up time/cycle time
l
164
EDBCSXA064 EN 3.2
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C2456
CAN time settings for CAN bus
interface X14 (CAN−AUX)
^ 163
1 CANa times
3000
0
{1 ms}
65000 CAN−AUX boot−up time:
Delay time after mains
connection for initialisation
through the master.
2 CANa times
0
CANaux2...3_OUT cycle times:
Factor for the task time to send
process data telegram.
0 = event−controlled
transmission
3 CANa times
0
4 CANa times
20
Delay time for initial
transmission of the process data
objects 2 and 3 after the CAN bus
changed to "Operational"
Save changes with C0003 = 1.
The settings are only accepted after carrying out one of the following actions:
ƒ
Renewed switch−on of the 24 V low−voltage supply
ƒ
Reset node via the bus system (by the network management (NMT))
ƒ
Variable CAN_bResetNode_b or CANaux_bResetNode_b = TRUE
ƒ
Reset node with C0358/2458 = 1
)
Note!
If reset node is executed via GDC, communication will be interrupted. You
therefore have to log in again manually or find the devices connected to the
bus once again (fieldbus scan).