System modules – Lenze ECSCAxxx User Manual
Page 265

System modules
AIF1_IO_AutomationInterface (node number 41)
Outputs_AIF1
l
265
EDBCSXA064 EN 3.2
System variables
Variable
Data
type
Signal
type
Address
Display
code
Display
format
Notes
AIF1_wDctrlStat
Word
˘
%QW41.0
˘
˘
AIF1_nOutW1_a
Integer
analog
%QW41.1
C0858/1
dec [%]
AIF1_nOutW2_a
%QW41.2
C0858/2
AIF1_nOutW3_a
%QW41.3
C0858/3
AIF1_bFDO0_b
...
AIF1_bFDO15_b
BOOL
binary
%QX41.2.0
...
%QX41.2.15
˘
hex
AIF1_bFDO16_b
...
AIF1_bFDO31_b
%QX41.3.0
...
%QX41.3.15
AIF1_dnOutD1_p
Double
integer
position
%QD41.1
C0859
dec [inc]
User data
The 8 bytes of user data to be sent can be written via several variables of different data
types. According to requirements, data can therefore be transferred from the PLC program
as
ƒ
binary information (1 bit)
ƒ
status word/quasi−analog value (16 bit)
ƒ
angle information (32 bit)
)
Note!
Avoid simultaneous overwriting via different variable types to ensure data
consistency.
Thus, bytes 5 and 6 should only be overwritten by
ƒ
variable AIF1_dnOutD1_p,
ƒ
variable AIF1_nOutW2_a or
ƒ
variables AIF1_bFDO0_b ... AIF1_bFDO15_b.
Byte
Variable (1 bit)
Variable (16 bit)
Variable (32 bit)
1, 2
AIF1_wDctrlStat
Byte 1/2 can be used for transferring the status word from the SB DCTRL_DriveControl to the field bus
module.
l
For this purpose, connect variable DCTRL_wStat of the SB DCTRL_DriveControl to variable
AIF1_wDctrlStat.
l
In addition to signals such as IMP and CINH the SB status word DCTRL_DriveControl contains some
freely assignable signals which can be overwritten via the variables DCTRL_bStateB..._b of the
SB DCTRL_DriveControl.
3, 4
AIF1_nOutW1_a
5, 6
AIF1_bFDO0_b
...
AIF1_bFDO15_b
AIF1_nOutW2_a
AIF1_dnOutD1_p
7, 8
AIF1_bFDO16_b
...
AIF1_bFDO31_b
AIF1_nOutW3_a