Appendix – Lenze ECSCAxxx User Manual
Page 414

Appendix
Code table
l
414
EDBCSXA064 EN 3.2
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C0603 MONIT CE5
3
Fault response − gateway
function monitoring (CE5)
"Timeout" when remote
parameter setting (C0370) is
activated via interface X4 (CAN)
^ 202
^ 180
0
TRIP
2
Warning
3
Off
C0604 MONIT OC7
2
Fault response − monitoring of
Ixt device utilisation.
Ixt threshold can be set under
C0123.
^ 205
0
TRIP
2
Warning
3
Off
C0605 MONIT OH5
2
Fault response − monitoring of
temperature inside the
controller.
Temperature threshold can be
set under C0124.
^ 209
0
TRIP
2
Warning
3
Off
C0606 MONIT OC8
2
Fault response − monitoring of
I
2
x t motor utilisation.
Threshold can be set under
C0120.
^ 214
0
TRIP
2
Warning
3
Off
C0607 MONIT NMAX
0
Fault response − maximum speed
monitoring of the machine
0
TRIP
2
Warning
3
Off
C0608 ovr. Tx−Queue
2
Fault response − transmission
memory overflow of free CAN
objects
0
TRIP
1
Message
2
Warning
3
Off
4
FAIL−QSP
C0609 ovr. Rx−Isr
0
Fault response Receive memory
overflow of free CAN objects
0
TRIP
4
FAIL−QSP