Appendix – Lenze ECSCAxxx User Manual
Page 413

Appendix
Code table
l
413
EDBCSXA064 EN 3.2
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C0593 MONIT CE3
3
Fault response − monitoring
CAN3_IN (no telegrams)
"CommErrCANIN3" (CE3)
^ 202
0
TRIP
2
Warning
3
Off
C0594 MONIT SD6
3
Fault response − monitoring
KTY sensor for the motor
temperature.
"SensorFault" (Sd6)
^ 223
0
TRIP
2
Warning
3
Off
C0595 MONIT CE4
3
Fault response − system bus
(CAN) monitoring "Bus−off" at X4
"BusOffState" (CE4)
^ 202
0
TRIP
2
Warning
3
Off
C0596 NMAX limit
5500
Maximum system speed
^ 227
0
{1 rpm}
16000
C0597 MONIT LP1
3
Fault response − monitoring of
motor phase failure (LP1)
When this function is activated,
the calculating time provided for
the user program is reduced!
^ 221
0
TRIP
2
Warning
3
Off
C0598 MONIT SD5
3
Fault response − master current
monitoring at X6 < 2 mA
"MastISourceDef"
^ 275
0
TRIP
2
Warning
3
Off
C0599 Limit LP1
5.0
Monitoring limit for motor phase
failure monitoring (LP1) with
regard to the current limit.
^ 221
0.01
{0.01 %}
10.00
C0602 MONIT REL1
3
Fault response − open circuit
monitoring of relay output X25
0
TRIP
2
Message
3
Off
4
FAIL−QSP