9 device status, System modules – Lenze ECSCAxxx User Manual
Page 328
System modules
DCTRL_DriveControl (node number 121)
Device status
l
328
EDBCSXA064 EN 3.2
13.15.9
Device status
The status bits 8 ... 11 in C0150 display the binary−coded device status of the axis module:
Status bit 11
Status bit 10
Status bit 9
Status bit 8
Description
0
0
0
0
Initialisation after connecting the
supply voltage
0
0
0
1
Switch−on inhibit / restart
protection active (C0142 = 0)
0
0
1
1
Controller inhibited
0
1
1
0
Controller enabled
0
1
1
1
A monitoring function returns a
"message".
1
0
0
0
A monitoring function returns a
"TRIP".
1
0
1
0
A monitoring function returns a
"FAIL−QSP".
0 = FALSE
1 = TRUE
Code
Possible settings
IMPORTANT
No.
Designation
Lenze/
{Appl.}
Selection
C0150 Status word
0
Device status word 1 (DCTRL)
Read only
^ 328
^ 327
0
{1}
65535 Controller evaluates information
as 16 bits (binary−coded)
Bit 0
Not assigned
DCTRL_bStateB0_b
Bit 1
Pulse inhibit (IMP)
DCTRL_bImp_b
Bit2
Not assigned
DCTRL_bStateB2_b
Bit3
Not assigned
DCTRL_bStateB3_b
Bit4
Not assigned
DCTRL_bStateB4_b
Bit5
Not assigned
DCTRL_bStateB5_b
Bit 6
n = 0
DCTRL_bNActEq0_b
Bit 7
Controller inhibit (CINH)
DCTRL_bCInh_b
Bit 8
Device status bit 1
DCTRL_bStat1_b
Bit 9
Device status bit 2
DCTRL_bStat2_b
Bit10
Device status bit 3
DCTRL_bStat4_b
Bit11
Device status bit 4
DCTRL_bStat8_b
Bit12
Warning
DCTRL_bWarn_b
Bit13
Message
DCTRL_bMess_b
Bit14
Not assigned
DCTRL_bStateB14_b
Bit15
Not assigned
DCTRL_bStateB15_b