AIF interface (X1) configuration
Monitoring
Time monitoring for XCAN1_IN ... XCAN3_IN
l
192
EDBCSXA064 EN 3.2
9.8
Monitoring
9.8.1
Time monitoring for XCAN1_IN ... XCAN3_IN
For the inputs of the process data objects XCAN1_IN ... XCAN3_IN a time monitoring can
be configured via C2357:
Code
Possible settings
IMPORTANT
No.
Designation
Lenze/ap
pl.
Selection
C2357
Monitoring time for XCAN
process data input objects
(AIF interface X1)
Only ECSxA: When the subcodes
1 ... 4 are set, consider the task
runtime:
C2357/1...4 = Desired monitoring
time / task runtime
^ 192
1 CE monit time
3000
1
{1 ms}
65000 XCAN1_IN monitoring time
2 CE monit time
3000
XCAN2_IN monitoring time
3 CE monit time
3000
XCAN3_IN monitoring time
4 CE monit time
3000
Bus−off
5 CE monit time
3000
AIF monitoring time (can only be
set if C2357/6 = 0)
6 CE monit time
0
Sync monitoring time (can only
be set if C2357/5 = 0)
The response, if no telegram has been received within the defined monitoring time, can be
configured via the code C2382/x:
Code
Possible settings
IMPORTANT
No.
Designation
Lenze/ap
pl.
Selection
C2382
The XCAN monitoring is
configured if no telegrams have
been received.
(AIF interface X1)
1 XCAN Conf. CE
0
Off
XCAN1_IN
2 XCAN Conf. CE
0
Off
XCAN2_IN
3 XCAN Conf. CE
0
Off
XCAN3_IN
4 XCAN Conf. CE
0
Off
Bus−off
5 XCAN Conf. CE
0
Off
Life Guarding / Heartbeat Event
6 XCAN Conf. CE
0
Off
Response to sync reception
0
Off
1
Controller inhibit (CINH)
2
Quick stop (QSP)