System modules – Lenze ECSCAxxx User Manual
Page 367
System modules
MCTRL_MotorControl (node number 131)
Adjusting the motor data
l
367
EDBCSXA064 EN 3.2
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C0083 DIS:Tr
Rotor time constant of the
asynchronous motor
Read only
0.00
{0.01 ms}
327.67
[C0084] Mot Rs
1.10
Stator resistance of the motor
The upper limit is
device−dependent.
0.00
{0.01
W}
95.44 ECSxS/P/M/A004
47.72 ECSxS/P/M/A008
23.86 ECSxS/P/M/A016
11.93 ECSxS/P/M/A032
7.95 ECSxS/P/M/A048
5.96 ECSxS/P/M/A064
[C0085] Mot Ls
5.30
Leakage inductance of the motor
0.00
{0.01 mH}
200.00
[C0087] Mot speed
3700
Rated motor speed
300
{1 rpm}
16000
[C0088] Mot current
7.0
Rated motor current
0.5
{0.1 A}
500.0
[C0089] Mot
frequency
185
Rated motor frequency
10
{1 Hz}
1000
[C0090] Mot voltage
325
Rated motor voltage
50
{1 V}
500
[C0091] Mot cos phi
1.0
cos
j of the asynchronous motor
0.50
{0.01}
1.00
C0092 DIS:Isdeff
Magnetising current of the
asynchronous motor
Read only
0.00
{0.01 A}
327,67
C0093 Drive ident
Device identification of the ECS
axis module
Read only
0
Defective power section
1
No power section recognised
4
ECSxS/P/M/A004C4
8
ECSxS/P/M/A008C4
16
ECSxS/P/M/A016C4
32
ECSxS/P/M/A032C4
48
ECSxS/P/M/A048C4
64
ECSxS/P/M/A064C4
65
ECSxS/P/M/A064C2
[C0095] Rotor pos adj
0
Activation of rotor position
adjustment for automatic
determination of the rotor
displacement angle.
C0058 displays the determined
rotor displacement angle (offset
angle).
^ 138
0
Inactive
1
Active