2 outputs_dctrl, System modules – Lenze ECSCAxxx User Manual
Page 323
System modules
DCTRL_DriveControl (node number 121)
Outputs_DCTRL
l
323
EDBCSXA064 EN 3.2
13.15.2
Outputs_DCTRL
System variables
Variable
Data
type
Signal
type
Address
Display
code
Display
format
Notes
DCTRL_wCAN1Ctrl
Word
˘
%QW121.3
˘
˘
CAN control word
DCTRL_wAIF1Ctrl
%QW121.2
Control word AIF
DCTRL_bCInh1_b
BOOL
binary
%QX121.0.1
C0878/1
bin
Controller inhibit
(
^ 325)
DCTRL_bCInh2_b
%QX121.0.2
C0878/2
DCTRL_bTripSet_b
%QX121.0.3
C0878/3
TRIP SET (
^ 326)
DCTRL_bTripReset_b
%QX121.0.4
C0878/4
TRIP RESET (
^ 326)
DCTRL_bStatB0_b
BOOL
binary
%QX121.1.0
˘
˘
Status signals (
^ 327)
DCTRL_bStatB2_b
%QX121.1.2
DCTRL_bStatB3_b
%QX121.1.3
DCTRL_bStatB4_b
%QX121.1.4
DCTRL_bStatB5_b
%QX121.1.5
DCTRL_bStatB14_b
%QX121.1.14
DCTRL_bStatB15_b
%QX121.1.15
Codes
Code
Possible settings
IMPORTANT
No.
Designation
Lenze/
{Appl.}
Selection
C0135 Control word
0
System control word DCTRL
0
{1}
65535 Controller evaluates information
as 16 bits (binary−coded)
Bit 0
Not assigned
Bit 1
Not assigned
Bit 2
Not assigned
Bit 3
Quick stop (QSP)
Bit 4
Not assigned
Bit 5
Not assigned
Bit 6
Not assigned
Bit 7
Not assigned
Bit 8
Operation inhibit (DISABLE)
Bit 9
Controller inhibit (CINH)
Bit 10
TRIP−SET
Bit 11
TRIP−RESET
Bit 12
Not assigned
Bit 13
Not assigned
Bit 14
Not assigned
Bit 15
Not assigned