System modules
SYSTEM_FLAGS (system flags, node number 151)
Outputs SYSTEM_FLAGS
l
373
EDBCSXA064 EN 3.2
SYSTEM_bTogCycleTask
This system flag alters the state with the cyclic task:
1. cycle: FALSE
2. cycle: TRUE
3. cycle: FALSE
4. cycle: TRUE
etc.
SYSTEM_nTaskInterval
This system flag indicates the interval of the running task with a resolution of 0.25 ms.
ƒ
If, for instance, a tasks of 10 ms is processed, the system flag indicates ’40’
(40 × 0.25 ms = 10 ms).
ƒ
If a task different from an interval task is processed, the system flag indicates 0".
SYSTEM_nTaskID
This system flag indicates the task ID of the running task.
SYSTEM_b1LoopCyclicTask/SYSTEM_b1Loop Task X
These system flags are TRUE only once during the first cycle of a task.
ƒ
After the first cycle, the flags will be set to FALSE.
ƒ
The only way to reset the status to TRUE is to reset the program in the drive
controller.
13.22.2
Outputs SYSTEM_FLAGS
Variable
Data type
Address
Comments
SYSTEM_bPLCResetAndRun
Bool
%QX151.0.0
This system flag executes a reset with
immediate restart of the axis module.
After the reset, the flag will be deleted
and a restart is executed.