Appendix, Code table – Lenze ECSCAxxx User Manual
Page 411
Appendix
Code table
l
411
EDBCSXA064 EN 3.2
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
[C0540] X8 Signal out
2
Function of the digital frequency
output signals on X8 (DFOUT)
^ 112
0
DFOUT in [%]
1
DFOUT in [rpm]
2
Encoder simulation + zero pulse
®
DFOUT
C0545 PH offset
0
Phase offset
^ 340
0
{1 inc}
65535 1 revolution = 65535 increments
C0547 DIS: AN−IN
Analog signal on the input of the
DFOUT block
Read only
^ 340
−199.99
{0.00 %}
199.99
C0549 DIS: DF−IN
Speed on the input of the DFOUT
block
Only display
^ 340
−32767
{1 rpm}
32767
C0559 SD8 filter t
1
Filter time constant (SD8)
1
{1 ms}
200 Example:
If the setting is "10 ms", a
SD8−TRIP is actuated after 10 ms.
C0576 nErr tolerance
100
Tolerance window for the speed
system deviation referring to
n
max
100 % = lowest monitoring
sensitivity
^ 226
0
{1 %}
100
C0577 Vp fld weak
0.100
Gain of the field weakening
controller (V
p
)
^ 144
0.000
{0.001}
63.999
C0578 Tn fld weak
3.0
Integral−action time of the field
weakening controller (V
n
)
0.1
{0.1 ms}
6000.0
C0579 nErr response
3
Fault response − monitoring of
speed system deviation
^ 226
0
TRIP
1
Message
2
Warning
3
Off
4
FAIL−QSP
C0580 Monit SD8
3
Fault response − monitoring of
SinCos signals at X8
^ 225
0
TRIP
3
Off
C0581 MONIT EEr
0
Fault response − external fault
monitoring "ExternalFault" (EEr)
^ 326
0
TRIP
1
Message
2
Warning
3
Off
4
FAIL−QSP