Troubleshooting and fault elimination – Lenze ECSCAxxx User Manual
Page 243
Troubleshooting and fault elimination
Fault messages
Overview of fault messages, error sources and responses
l
243
EDBCSXA064 EN 3.2
System error message
Possible settings/response
· Lenze setting
ü Setting possible
Available in
No.
Display
Source
Meaning
Code
TRIP
Messa
ge
Warni
ng
FAIL−Q
SP
Off
Drive
PLC
Servo
PLC
ECSxA
x070 U15
Internal Undervoltage of internal 15 V
voltage supply
·
ь
ь
ь
x071 CCr
Internal Internal fault
1)
·
ь
ь
ь
x072 PR1
Internal Checksum error in parameter
set 1
·
ь
ь
ь
x074 PEr
Internal Program error
1)
·
ь
ь
ь
x075 PR0
Internal General parameter set fault
1)
·
ь
ь
ь
x076 PR5
Internal Error saving parameters
·
ь
ь
x079 PI
Internal Fault during parameter
initialisation
1)
·
ь
ь
ь
x080 PR6
Internal Too many user codes
·
ь
ь
ь
x082 Sd2
MCTRL
Resolver error
C0586
·
ь
ь
ь
ь
x083 Sd3
MCTRL
Encoder error at X9 pin 8
C0587
ь
ь
·
ь
x085 Sd5
MCTRL
Encoder error at analog input
(X6) (C0034 = 1)
C0598
ь
ь
·
ь
ь
x086 Sd6
MCTRL
Motor temperature sensor
error (X7 or X8)
C0594
·
ь
ь
ь
ь
x087 Sd7
MCTRL
Absolute value encoder error
at X8
1)
C0025
·
ь
ь
x088 Sd8
MCTRL
Absolute value encoder error
at X8
1)
C0580
ь
·
ь
ь
x089 PL
MCTRL
Error during rotor position
adjustment
·
ь
ь
x091 EEr
FWM
External monitoring actuated
via DCTRL
C0581
·
ь
ь
ь
ь
ь
ь
x105 H05
Internal Internal fault (memory)
·
ь
ь
ь
x107 H07
Internal Internal fault (power section)
·
ь
ь
x108 H08
Internal Extension board not
connected correctly or not
supported by program
·
ь
ь
x110 H10
FWM
Heatsink temperature sensor
error
C0588
·
ь
ь
ь
x111 H11
FWM
Thermal sensor error in the
interior of the device
·
ь
ь
ь
x: 0 = TRIP, 1 = Message, 2 = Warning, 3 = FAIL−QSP
1)