1 inputs_canaux1, System modules – Lenze ECSCAxxx User Manual
Page 306
System modules
CANaux1_IO (node number 34)
Inputs_CANaux1
l
306
EDBCSXA064 EN 3.2
13.12.1
Inputs_CANaux1
System variables
Variable
Data
type
Signal
type
Address
Display
code
Display
format
Comments
CANaux1_nInW0_a
integer
analog
%IW34.0
˘
˘
CANaux1_bInB0_b
%IX34.0.0
...
BOOL
binary
...
C2491/1
hex
CANaux1_bInB15_b
%IX34.0.15
CANaux1_nInW1_a
integer
analog
%IW34.1
C2492/1
dec [%]
CANaux1_bInB16_b
%IX34.1.0
...
BOOL
binary
...
C2491/2
hex
CANaux1_bInB31_b
%IX34.1.15
CANaux1_nInW2_a
integer
analog
%IW34.2
C2492/2
dec [%]
CANaux1_bInB32_b
%IX34.2.0
...
BOOL
binary
...
˘
˘
CANaux1_bInB47_b
%IX34.2.15
CANaux1_nInW3_a
integer
analog
%IW34.3
C2492/3
dec [%]
CANaux1_bInB48_b
%IX34.3.0
...
BOOL
binary
...
˘
˘
CANaux1_bInB63_b
%IX34.3.15
CANaux1_dnInD1_p
double
integer
position
%ID34.1
˘
˘
User data
The 8 bytes of received user data are assigned to several variables of different data types.
According to requirements, they can thus be evaluated by the PLC program as:
ƒ
binary information (1 bit)
ƒ
control word/quasi−analog value (16 bit)
ƒ
angle information (32 bit)
Byte
Variable (1 bit)
Variable (16 bit)
Variable (32 bit)
1, 2
CANaux1_bInB0_b
...
CANaux1_bInB15_b
CANaux1_nInW0_a
3, 4
CANaux1_bInB16_b
...
CANaux1_bInB31_b
CANaux1_nInW1_a
5, 6
CANaux1_bInB32_b
...
CANaux1_bInB47_b
CANaux1_nInW2_a
CANaux1_dnInD1_p
7, 8
CANaux1_bInB48_b
...
CANaux1_bInB63_b
CANaux1_nInW3_a