beautypg.com

System modules – Lenze ECSCAxxx User Manual

Page 282

background image

System modules

CAN_Synchronization (node number 102)

13

l

282

EDBCSXA064 EN 3.2

Codes

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0363 Sync correct.

1

CAN sync correction increment

^ 167

1

0.2

ms/ms

2

0.4

ms/ms

3

0.6

ms/ms

4

0.8

ms/ms

5

1.0

ms/ms

C0366 Sync Response

1

CAN sync response for interface
X4 (CAN)
The value "1" should always be
set!

^ 169

0

No response

1

Response

C0367 Sync Rx ID

128

CAN sync receipt ID for CAN bus
interface X4

^ 168

1

{1}

256

C0368 Sync Tx Id

128

CAN Sync transmission ID for
CAN bus interface X4

^ 442

^ 166

1

{1}

256

C0369 SyNc Tx time

0

CAN sync transmission cycle for
CAN bus interface X4
A sync telegram with the
identifier of C0368 is sent with
the cycle time set.
ECSxP: The setting is effected
automatically depending on
C4062!

^ 167

0

{1 ms}

65000 0 = switched off

C1120 Sync mode

0

Sync signal source

^ 166

0

Off

Off

1

CAN sync

Sync connection via interface X4
(CAN)

^ 170

2

Terminal sync

Sync connection via terminal
X6/DI1

^ 171

C1121 Sync cycle

2

Synchronisation cycle

^ 166

1

{1 ms}

13

C1122 Sync phase

0.460

Synchronisation phase

^ 167

0.000

{0.001 ms}

6.500

C1123 Sync window

0.010

Synchronisation window

^ 169

0.000

{0.001 ms}

6.500

This manual is related to the following products: