Appendix, Code table – Lenze ECSCAxxx User Manual
Page 404

Appendix
Code table
l
404
EDBCSXA064 EN 3.2
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
[C0370] SDO gateway
0
Activate address
gateway/remote
parameterisation
The SDO gateway cannot be
used to read out codes >C2000
or codes of the Inverter Drives
8400 and Servo Drives 9400.
l
C0370
¹ 0: All code
write/read accesses are
redirected to the CAN node
with the CAN node address
set here.
l
The corresponding code is
accessed via parameter data
channel 1 of the target device.
l
C0370 = 0: remote
parameterisation is
deactivated
^ 180
0
{1}
63
C0371 Gateway Ch.
1
Selection of the gateway channel
^ 180
0
CAN
Use CAN bus interface X4
1
CAN−AUX
Use CAN bus interface X14
C0381 HeartProdTim
e
0
Heartbeat (slave):
HeartbeatProducerTime
l
Time interval for sending the
heartbeat message
l
Only relevant for setting
C0352 = 3.
0
{1 ms}
65535
C0382 GuardTime
0
Node Guarding (slave):
NodeGuardTime
l
Time interval of the status
inquiry of the master
l
Only relevant for setting
C0352 = 4.
^ 172
0
{1 ms}
65535
C0383 LifeTimeFact
0
Node Guarding (slave):
NodeLifeTime factor
l
Factor for the monitoring
time of NodeLifeTime
l
NodeLifeTime = C0383 x
C0382 (NodeGuardTime)
l
Only relevant for setting
C0352 = 4.
^ 172
0
{1}
255
C0384 Err
NodeGuard
3
Node Guarding (slave)
l
Response for the occurrence
of a NodeGuard−Event
l
Only relevant for setting
C0352 = 4.
^ 172
0
TRIP
1
Message
2
Warning
3
Off
4
FAIL−QSP