Electrical installation – Lenze ECSCAxxx User Manual
Page 101
Electrical installation
Wiring of the feedback system
Digital frequency input/output (encoder simulation)
l
101
EDBCSXA064 EN 3.2
ƒ
2 to 3 slaves connected to the master:
Use the EMF2132IB digital frequency distributor to wire the ECS axis modules with
master digital frequency cable EYD0017AxxxxW01W01 and slave digital frequency
cable EYD0017AxxxxW01S01.
X8
X8
X8
X8
0
1
1
1
E-Shaft Master
Slave 3
Slave 2
Slave 1
X
S
PLC
X4
X4
X4
X4
120
ECS
ECS
ECS
ECS
X1
X5
X2 X3 X4
EMF2132IB
120
120
X14
X14
X14
X14
120
120
120
ECSXP001
Fig. 5−22
ECS axis modules in the digital frequency network with digital frequency distributor EMF2132IB
PLC
Master control (PLC) or a PLC device to control the drive system
E−Shaft master Master value master (axis module ECSxP)
Slave 1...3
Slave 1, slave 2, slave 3 (axis module ECSxP)
0
Master digital frequency cable EYD0017AxxxxW01W01 (socket/socket)
1
Slave digital frequency cable EYD0017AxxxxW01S01 (plug/socket)
I
Tip!
"xxxx" in the type designation of the digital frequency cables serves as a
wildcard for the specification of the cable length in decimetres.
Example: EYD0017A0015W01W01
® cable length = 15 dm